1
1. Preface
This manual describes necessary procedure to perform PB motor operation as a startup guide. Refer manual
M-E099GA0C2-191 for detail.
Please use application software
“
MEGATORQUE MOTOR SETUP
”
to set parameter setting value of model
EGA driver.
“
MEGATORQUE MOTOR SETUP
”
is a free software which can be downloaded from NSK
Website.
2. System configuration
Noise filter
Installed to protect power line from
external noise.
防ぐために取り付けます。
Citcuit Breaker
Used to protect power line.
Turns off the power supply when
overload runs.
MEGATORQUE
MOTOR SETUP
Enables parameter set up and monitoring
through communication with a PC.
Host equipment
Switches power On/Off.
Please place safeguard circuit.
T S R
Electromagnetic contactor
Converter cable
Motor cable
RS-232C
Motor
For high-frequency operation, use an external
regenerative resistor.
External regenerative resistor
Converter