3. SPECIFICATIONS
3-1. Converter Specifications
(1) General Specification
Items Specifications
Power supply voltage
24VDCV
±
10% (including ripple)
Power consumption
7W or less
Insulation resistance
20 M-Ohms or more between external DC power terminals and ground
(by 500 VDC insulation resistance tester)
Withstand voltage
500 VAC, 60Hz for 1 minute between external DC power terminal and
ground
Vibration resistance
20m/s
2
10 to 500Hz, 10cycles of 5 minutes in 3 directions,
conforms to JIS C 0040 standard
Ambient operating temperature
0 to +55°C (No freezing)
(Surrounding air temperature rating of 55°C maximum)
Ambient operating humidity
20 to 90 %RH (No condensation)
Ambient operating environment Free from corrosive gases and excessive dust
Ambient storage temperature
-10 to +70°C
Grounding
Must be securely grounded (ground resistance of 100 ohm or less)
Construction
Book-shelf type within enclosure, DIN rail mountable
Outside dimension (mm)
39(W) x 155(H) x 93(D) Refer to dimensions for details.
Mass
Approx. 0.4kg
(2) Performance Specification
Items Specifications
Converter model
NCV-20NBNVP
NCV-20NGNVP
Applicable sensor
VRE-P028
VRE-P062
Total number of divisions
8192 (2
13
)
Output code
Binary :
13-bit
Gray:
13-bit
Number of detection axes
1
Position data sampling time
0.2ms
Status output signal
Latch pulse (Position data reading timing): 1 point
Sensor disconnected error (Positive logic): 1 point
Sensor disconnected error (Negative logic): 1 point
Input signals
Position data hold signal: 1 point
Control panel function
Current position setting
Position data increase/decrease direction setting (CW / CCW) :1point
0.2ms
High-speed
0.4ms
12.8ms
25.6ms
Position data
update cycle
Low-speed
51.2ms
Transparent format
Switch
(on rear face of product)
HOLD signal
format
PC synchro format
Monitor LED
Display of sensor disconnected error, Display of position data,
Display of latch pulse output, Display of HOLD signal format status
Applicable standard
UL508
(File No. E257113)
CSA C22.2 No.14-95 (Compliance with UL standard)
CE marking (EMC directive)
4