Powerporter 15.0 

User Manual 

 
 
 
 

 
 
 
 
 

 

Version 1.0 

 

 

 

nRuiT strongly advises to take due care in following the User manual. A warranty 
claim is invalid if damage is caused by human error, inconsistent. 

 

 

 

Содержание Powerporter 15.0

Страница 1: ...Powerporter 15 0 User Manual Version 1 0 nRuiT strongly advises to take due care in following the User manual A warranty claim is invalid if damage is caused by human error inconsistent ...

Страница 2: ...prohibited PRODUCT SPECIFICATIONS This manual applies to the product Powerporter 15 0 All specifica ons and descrip ons contained in this document are verified to be accurate at the me of prin ng However because con nuous improvement is a goal at nRuiT we reserve the right to make product modifica ons at any me The images provided in this document are for demonstra on purposes only Depending on produ...

Страница 3: ... Loca on 11 4 Interface Defini on 12 Powerporter interface panel 12 LED status indicators 12 CAN RS485 Interface Defini on 13 Schema c diagram of connec on with inverter simple connec on 14 Schema c diagram of connec on with inverter recommended connec on 14 Powerporter power Parallel opera on Compa ble inverter brand 16 17 cable connec on 14 Powerporter on and off 19 Powerporter Communica on Interfa...

Страница 4: ...situa on which If not avoided it may cause minor injury and or property damage NOTE Indicates a risk of possible damage to the product WARNING INFORMATION 1 Powerporter installa on must be carried out only by nRuiT Cer fied Installers who have been trained 2 In the power regula on circuit due to the high voltage there is a high possibility of electric shock or severe burns 3 High voltage on AC and ...

Страница 5: ...someone Check the cable of your product regularly If its appearance shows damage or deteriora on stop using this product and contact a qualified person to replace the cable 14 Make sure that the product you are connec ng is grounded to prevent possible electric shock Do not a empt to achieve grounding by connec ng the product to telephone lines lightning rods or gas pipes 15 If the Powerporter is d...

Страница 6: ... to which the product is adapted otherwise the product may be damaged 28 Never use any solvents abrasives or corrosive substances to clean this product 29 Do not store or place any objects on the product It may cause serious defects or malfunc ons 30 Before connec ng the product to the inverter terminal make sure that the product is turned off the inverter is turned off and the mains and PV channels...

Страница 7: ...e Temperature 10 to 45 Remarks The power porter needs to keep the ambient temperature within the range of 0 45 during startup Care and Cleaning If installed outdoors please ensure that there are no leaves and other debris around the Powerporter to maintain op mal airflow CAUTION Do not lean stack or hang anything around Powerporter and from wires to Powerporter CAUTION When cleaning the Powerporter...

Страница 8: ...ent Powerporter only maintains electrical connec on with the inverter The electrical energy generated by the PV is converted by the inverter Dc to DC and stored in the connected Powerporter When Powerporter is needed Powerporter s electrical energy is converted by the inverter DC to AC and transmi ed to the home grid to provide power for household appliances The main func on of the home energy sto...

Страница 9: ...ing compa ble with a variety of inverters The inverter you use does not necessarily contain all the above func ons Monitoring Your System Using the app you can monitor system opera on from your mobile device including the following Real me power usage Energy consump on history Rela ve amounts of energy used from solar grid and Powerporter storage Abbrevia on of manual Abbrevia o n Full Name Explan...

Страница 10: ...rgy storage ba ery 2 Power Cables 4 Connect with the inverter to carry out power transmission with it 3 COM Cable 1 Connect with inverter and communicate with it 4 User Manual 1 Model Name Battery Yype Rated Energy Capacity Voltage charge Voltage Max Continuous DC Power Series Number Powerporter 15 0 Li ion LiFePO4 15 46 kwh 302Ah 51 2V 51 5V 54V 10Kw ...

Страница 11: ... The suitable operating temperature of the product is 0 45 Do not install this product in direct sunlight Install the product in a clean and cool room This product must not be installed or used at an altitude of more than 2000 meters Do not install this product in the place where frequent flooding occurs Do not install this product in a bathroom with high humidity This product generates low noise ...

Страница 12: ...und 15 POWER Power on off LED status indicators No Project Explana on 1 PAR_A Parallel Port A 2 PAR_B Parallel Port B 3 COM DEBUG 4 CAN Communica on with Inverter 5 RS485 Communica on with Inverter 6 DRY Dry contact 7 ADR Address defini on 8 RST Product reset 9 RUN Run LED 10 ALM Alarm LED 11 SOC LED SOC LED ...

Страница 13: ... SOC 100 Blinki ng 66 SOC 83 Blinki ng 50 SOC 66 Blinki ng 33 SOC 50 Blinki ng 16 SOC 33 Blinki ng 0 SOC 16 Blinki ng Blinki ng Discharg e 83 SOC 100 Blinki ng 66 SOC 83 Blinki ng 50 SOC 66 Blinki ng 33 SOC 50 Blinki ng 16 SOC 33 Blinki ng 0 SOC 16 Blinki ng Blinki ng SOC 0 Protec on Failure CAN RS485 Interface Defini on Pin Defini on C A N RS4 85 Pin Define Pi n Define 1 2 3 6 8 1 8 485 B 4 CAN H 2 7...

Страница 14: ...a quick plug interface and the posi ve and nega ve poles can be dis nguished by color orange indicates the posi ve pole black indicates the negative pole and the installer can directly connect the power cables to the posi ve and nega ve poles of the product when wearing protec ve gloves The power cable is connected with the Powerporter through a quick plug interface and connected with the inverter...

Страница 15: ...nector is connected to the posi ve port of the Powerporter Warning Before the installa on of the power cables the Powerporter and the inverter must be turned off Power cables disconnec on steps Make sure the mains line is open and the PV line is open Turn off the inverter switch Press the POWER bu on to turns off Powerporter Remove the quick plug connector of the nega ve power cables Remove the quick...

Страница 16: ..._A of ba ery 2 Connect PAR_B of ba ery 2 to PAR_B of ba ery 3 Battery No 1 Battery No 2 ON DIP ADR Button Set 1 1 2 3 4 ON DIP 1 2 3 4 ADR Button Set 2 PAR_A OUT RS485 CAN IN PAR_A IN RS485 CAN OUT Parallel Box Parallel Box ON DIP ADR Button Set 1 1 2 3 4 ON DIP 1 2 3 4 ADR Button Set 2 PAR_A OUT PAR_B OUT RS485 CAN IN PAR_B IN PAR_A IN RS485 CAN OUT Parallel Box Parallel Box Battery No 1 Battery ...

Страница 17: ...ery 1 to RS485 CAN of inverter 1 Set the Bu on ADR of ba ery 1 to 1 Set the Bu on ADR of ba ery 3 to 3 Connect BMS of Inverter 1 to BMS of Inverter 2 Set the Bu on ADR of ba ery 2 to 2 Set the Bu on ADR of ba ery 4 to 4 Inverter No 1 Inverter No 2 RS485 CAN IN OUT RS485 CAN IN ADR Button Set 4 ON DIP 1 2 3 4 Parallel Box Parallel Box ON DIP ADR Button Set 1 1 2 3 4 ON DIP 1 2 3 4 ADR Button Set 2 ...

Страница 18: ...Deye GoodWe MEGAREVO SRNE Inverter Type SPF5000 ES SPF5000 HVM SNA5000 LXP 5K Hybrid Apollo Max 3 0 5 0 SUN 5K SG03LP1 EU GW5048D ES R5KLNA HF4850S80 Communica on CAN CAN CAN CAN CAN CAN CAN RS485 The following inverter brands have been tested by nruit laboratory and can be perfectly compa ble with powerporter 18 ...

Страница 19: ...d on off which is normal Warning The power on and power off ac ons of the POWER bu on are not emergency opera ons for security incidents If there is a safety problem in the home energy storage system please disconnect the leakage switch and isola on switch in the distribu on box in me Confirma on required Powerporter Communica on Interface Both CAN and RS485 interfaces are responsible for the communi...

Страница 20: ...ted to nRuiT or nRuiT authorized service partner within 2 weeks a er the failure the warranty is invalid 38 If you cannot communicate with the inverter through the applica on make sure that the Internet connection is normal 39 If neither the inverter nor the power switch responds Turn off the inverter Cut off all input and output circuit breakers in the distribu on box Press the POWER bu on to turn ...

Страница 21: ... all input and output circuit breakers in the distribu on box 43 Acceptable fire ex nguisher types include water CO2 and ABC fire ex nguishers Avoid using type D flammable metal fire ex nguishers In case of flood 44 If any part of the ba ery and inverter or wires are submerged in water please keep away from water 45 Turn off the inverter 46 Press POWER bu on to turn off Powerporter 47 Cut off all input an...

Страница 22: ...roduct and should not be stored for a long me Regardless of the reasons why the product is shut down and not used please observe the Powerporter storage requirements in the following table storage temperature Short term storage of less than 1 month 10 45 Long term storage of no more than 3 months 0 45 Do a full charge and discharge of the ba ery before the storage of the product expires and the fin...

Страница 23: ...ing the free Warranty period I Repair the nonconforming or defective products or II provide the buyer with replacement parts nRuiT shall be responsible for all reasonable repair or replacement costs associated with such non conforming or defective products however the buyer shall bear the cost of removing the defective products and re installing the repaired or replacement products 2 2 Limitation ...

Страница 24: ...sed as new or refurbished condition which performance is equal to or higher than defective Products and guaranteed by nRuiT In the event the Products are not available in the market anymore nRuiT at its option may replace it with different kind of product with equivalent functions and performances 5 Product Recycling Service Customers are provided with product recycling services after the end of p...

Страница 25: ...to be of acceptable quality and the failure does not amount to a major failure The benefits to the consumer given by the warranty are in addition to any other rights and remedies of the consumer under a law in relation to the goods or services to which the warranty relates This Warranty only applies to the Buyer who have purchased the Products for their own use S N Code The installation date User ...

Страница 26: ... Copyright 2022 nRuiT All rights reserved ...