background image

20

b

asic

 

seTTings

 

National Rejectors, Inc. GmbH, Buxtehude 

SRG –  Internal HENRI functions

Altering display contrast

The default setting of the display contrast is "46". To alter the contrast:

Press 

HENRI

 key.

 

You enter the main menu:

Press 

C

 key to open the 

s

eTTings

 menu:

Press 

B

 key to open submenu 

c

onTrasT

.

•  Use 

A

 key (up-arrow) to increase the contrast.

Use 

• 

B

 key (down-arrow) to decrease the contrast.

Use 

ExIT

 key to return to the main menu.

Содержание HENRI

Страница 1: ...1614 Buxtehude Phone 49 0 41 61 729 0 Fax 49 0 41 61 729 115 E mail info nri24 com Internet www nri24 com Technical Documentation Service tool HENRI Short reference guide for proceeding internal HENRI functions 06 10 JMo Roe Version 2 0 KA HENRI EN ...

Страница 2: ......

Страница 3: ...8 3 Safety instructions 9 Proper use 9 Protecting yourself and equipment 10 4 Design 11 Operating elements 11 Functions of the operating keys 12 Multifunction keys A to F 12 c2 menu key MENU 12 General menu key HENRI 12 Navigating in the menus 13 Main menu currenza c 13 General main menu HENRI 13 Switching between the main menus 14 From the general HENRI main menu to the c2 main menu 14 From the c...

Страница 4: ...eys system time memory 22 Testing keys system time memory and HENRI c2 interfaces 23 Firmware update 25 Calling up current firmware version 25 Updating firmware 25 Downloading the new firmware and FW updating PC application from the internet 26 Installing HenriFlash 26 Installing new firmware in HENRI tool Uploading new c2 firmware in HENRI tool 26 8 G 46 E 66 A 66 Configuration 29 The basics 29 K...

Страница 5: ...the HENRI service tool the NRI coin changercurrenzac2 andforaG 46orE 66 A 66 configurationthe G 55 0460 manual for the old service tool must be read carefully PDF download at www nri24 com Text conventions To make it easier for you to navigate within these instructions and to operate the devices the following accentuations were made in the text Safety instructions which you must observe in order t...

Страница 6: ...ernal HENRI functions Additional technical documentationen Apart from the short reference guide you already have there is further documentation for the service tool and the NRI coin changers All product descriptions are available in a compressed PDF format at www nri24 com Download ...

Страница 7: ...pdate firmware of NRI coin changers read out statistical data of the coin changer currenza c 2 This short reference guide only describes the general operation and proceeding of internal HENRI functions cp further manuals HENRI features One configuration tool for the NRI changers currenza c 2 G 46 F4xxx and E 66 A 66 with different vending machine interfaces Simple connection on site at the machine...

Страница 8: ...for the HENRI service tool WinSPT basic kit MDB with EURO plug ordering code 24688 with USA plug ordering code 24854 WinSPT accessory kit BDV Executive ordering code 26218 JVI VCCS ordering code 26215 SIM card ordering code 32845 for automatic c 2 data block firmware updates as licence for currenza heartbeat PC configuration software ...

Страница 9: ... the device Proper use The HENRI service tool is used for operation diagnostics configuration and general service work on the NRI coin changers currenza c2 G 46 F4xxx and E 66 A 66 Only use the service tool for this purpose Under no circumstances can the manufacturer be held liable for any damage or loss resulting from improper use of the device The service tool has been constructed in compliance ...

Страница 10: ...e label of the changer has been adapted to the new settings or the new settings are written down in another way for the workshop and the installation place The coin validator changer and HENRI PCBs are fitted with components which may be damaged beyond repair by electro static discharge Please observe the handling instructions for components exposed to the risk of electrostatic discharge Do not al...

Страница 11: ... key MENU for internal c2 functions Slot SIM card 3 Operating elements Fig 1 1 3 2 7 6 4 5 USB port PC 4 Multifunction keys A F 5 Display 6 Connecting cable RJ 45 plug 8 pole 7 payment system To operate and service the coin changer connected the service tool is equipped with a display 1 6 six multifunction keys 1 5 and two menu keys 1 1 2 It can be connected to an NRI payment system e g coin chang...

Страница 12: ...NU key 1 2 you enter the main menu for operation con figuration and service work on the coin changer currenza c Using this main menu you are able to select the internal c2 functions The menu is only available if HENRI is connected to a currenza c If not the key has no function This short reference guide only describes the general operation and proceeding of internal HENRI functions cp further manu...

Страница 13: ...Main menu currenza c In the main menu for the coin changer currenza c you select the submenu required by pressing the multifunction key with the character A B C D E or F on the left hand side of the menu In the submenu you navigate with the down arrow or up arrow keys to select a certain menu item OK key to enter the menu selected Exit key to return to the superordinate menu MENU key to switch ove...

Страница 14: ...t and wait for ap prox 30 sec until a new connection has been set up From the general HENRI main menu to the c2 main menu With the Exit key back to the HENRI main menu With the menu key MENU to the c2 start screen first and then With the menu key MENU to the c2 main menu From the c2 main menu to the general HENRI main menu With the Exit key back to the c2 main menu With the menu key MENU to the c2...

Страница 15: ...op by using a tester Connecting HENRI on site In order to connect HENRI to a coin changer plug the RJ 45 connector western plug of the connecting cable into the socket on the top right of the coin changer see Fig As HENRI identifies the connected payment system automatically the display shows device specific data after the connection with the payment system has been established Connecting HENRI on...

Страница 16: ...refer to our product accessory pages on the internet www nri24 com If necessary connect 24V power pack to appropriate power cable 1 Connect WinSPT tester to power pack using the DC interface 2 Connect WinSPT tester to e g coin changer using the MDB inter 3 face and the machine connecting cable if necessary by means of the adapter cables which are part of the accessory kits for other ma chine inter...

Страница 17: ...n is device dependent currenza c2 If HENRI is connected to a currenza c HENRI displays two start screens and switches then over to the c mode automatically in order to display the selected status message if there is no error e g E 66 A 66 If HENRI is connected to an E 66 A 66 HENRI displays two start screens E 66 A 66 G 46 If HENRI is connected to a G 46 HENRI displays two start screens G 46 ...

Страница 18: ...ime Display contrast Baud rate Setting menu language HENRI supports the following languages English French German Italian Dutch option Spanish option Default language is English when HENRI is delivered If another language is to be set Press 1 HENRI key You enter the main menu Press 2 C key to open the Settings menu Press 3 A key to open submenu Language Press 4 A or B key to select the language Us...

Страница 19: ...m time In this case time setting is not necessary Press 1 HENRI key You enter the main menu Press 2 C key to open the Settings menu Press 3 C key again to open submenu Date Time Set date format day month year and time 4 format hour mi nute second use D or C key reight arrow left arrow to mark data to be changed use A key up arrow to increase data selected use B key down arrow to decrease data sele...

Страница 20: ...ault setting of the display contrast is 46 To alter the contrast Press 1 HENRI key You enter the main menu Press 2 C key to open the Settings menu Press 3 B key to open submenu Contrast Use 4 A key up arrow to increase the contrast Use B key down arrow to decrease the contrast Use 5 Exit key to return to the main menu ...

Страница 21: ...e baud rate is set to 57600 In case the baud rate must be adapted manually e g for a coin changer firmware update Press 1 HENRI key You enter the main menu Press 2 A key to open the Update menu Press 3 E key to open submenu CC baud rate Use 4 A B C key to select the baud rate Use 5 Exit key to return to the main menu ...

Страница 22: ...y chips or in addition all HENRI interfaces as well as the c2 vending machine in terface Testing keys system time memory To test the operational capability of the service tool Connect HENRI to a voltage source see Chap 5 Connection 1 In case HENRI is connected to a PC it switches over to the main menu automatically if not Press 2 HENRI key You enter the main menu Press 3 B key to open the menu Ext...

Страница 23: ...is defective In this case please contact your service technician Use 6 Exit key to return to the main menu Testing keys system time memory and HENRI c2 interfaces To additionally test the HENRI interfaces as well as the currenza c2 vend ing machine interface Connect HENRI to a voltage source see Chap 5 Connection 1 In case HENRI is connected to a PC it switches over to the main menu automatically ...

Страница 24: ...y A to F HENRI MENU System time EPROM Flash memory SIM card slot currenza c vending machine interface CX2 slave CX2 master RJ 45 interface USB port The results of the function tests are displayed with OK if HENRI components are free from defects ERR if at least one component is defective In this case please contact your service technician Use 6 Exit key to return to the main menu ...

Страница 25: ...rent firmware version To determine the current HENRI FW version Press 1 HENRI key You enter the main menu Press 2 C key to open the Settings menu Press 3 D key to call up the current FW version of the service tool in submenu Firmware no SxxBxx 9200382xxxx Use 4 Exit key to return to the main menu Updating firmware For updating the FW you will require the PC application HenriFlash which you can dow...

Страница 26: ...nsion cxb mot dsp These files represent the current FW for the currenza c2 coin changer cp separate c2 service manual Sart exe file and follow the installation wizard 2 HenriFlash is installed Installing new firmware in HENRI tool Uploading new c2 firmware in HENRI tool There are two aspects to consider using the HenriFlash application A Installing a new HENRI firmware itself or B Loading the curr...

Страница 27: ...ton After having selected all firmware files required HenriFlash is ready for a firmware update or simple upload First connect the USB cable provided to a PC USB port Then 5 A If the HENRI firmware is to be updated Installation Press and hold the Menu button on the HENRI tool while con necting the free end of the USB cable to HENRI Wait until the HENRI tool has started the bootloader mode Release ...

Страница 28: ...nternal HENRI functions Click on the 6 Update button on the HenriFlash screen to start the firmware installation upload HenriFlash displays the data transfer status in the right hand Output field Please refer to the c2 service manual to install new c2 firmware ...

Страница 29: ...ake The basics The old G 46 E 66 A 66 setting module G 55 0460 has been displaced by the new service tool HENRI As the HENRI tool in the first instance has been developed to operate and maintain the c2 coin changers HENRI provides an extra G 46 E 66 A 66 mode offering the same menu structure and navigation as the old setting module The only difference in operating the tool is the key functions Key...

Страница 30: ...ENRI changes to the G 46 E 66 A 66 mode automatically G 46 or E 66 A 66 1b Press HENRI key You enter the main menu HENRI menu A FW update B Exten funkt C Settings D Changer modes E DB update MENU CC menu Press key to open the Changer modes Changer modes A c2 B E A 66 G 46 C Palm settings EXIT Exit Press key to access the G 46 E 66 A 66 mode G 46 or E 66 A 66 2 Proceed as normal and press the key i...

Страница 31: ...ssed the HENRI key by mistake you enter either the A main menu or the B Changer modes menu To return to the G 46 E 66 A 66 mode just press the key and then the key A HENRI menu A FW update B Exten funkt C Settings D Changer modes E DB update MENU CC menu Changer modes A c2 B E A 66 G 46 C Palm settings EXIT Exit E 66 A 66 B Changer modes A c2 B E A 66 G 46 C Palm settings EXIT Exit E 66 A 66 ...

Страница 32: ...ata information about the CE certification Device data Supply voltage Via USB or RJ 45 interface Temperature range 10 C to 50 C Rel humidity Up to 90 Interfaces PC USB NRI coin changer RJ 45 Device dimensions Height 157mm without cable Width 83mm without cable Depth 21mm Connecting cable Length approx 100cm Mark of conformity CE see next section ...

Страница 33: ...n the declaration of conformity The manufacturer must keep this declaration available for the monitoring authorities only for a minimum period of 10 years after the last product has been introduced to the market However upon request we can provide copies of this declaration for our customers The following directives and their subsequent changes can be applied to our devices The EMC Directive 2004 ...