Instruction Manual 

for 

P-2062 Ionizer & Accessories

 

 

 

 

 

CONTENTS 

 
1.0  Model P-2062 Ionizer                                         Page 1 
 
2.0  Accessories                                                         Page 2 
            2.1  Model 4067 Fan 
 
3.0  Troubleshooting                                                  Page 3 
 
 

 
 

 

Содержание P-2062

Страница 1: ... WEB www nrdllc com NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com INST2060 2 19 Instruction Manual for P 2062 Ionizer Accessories CONTENTS 1 0 Model P 2062 Ionizer Page 1 2 0 Accessories Page 2 2 1 Model 4067 Fan 3 0 Troubleshooting Page 3 ...

Страница 2: ... in close proximity to the ion cell can also be effectively neutralized without the need of air movement 1 1 Installation Operation A The P 2062 is to be installed in a customer supplied mounting fixture Mount the P 2062 using the two 0 14 diameter mounting holes on the front plate Locate in a suitable air stream to deliver the ions to the area to be neutralized Do not alter the P 2062 in any way ...

Страница 3: ...062 This system delivers a high volume of ionized air to reduce charge on parts The Fan is mounted on a swivel base and can be placed on a flat surface or bolted to a rigid surface Procedure to install a new P 2062 Ionizer A Unplug AC adapter from the electrical outlet B Remove two 2 thumb screws C Slide the model P 2062 into opening in middle plate make sure holes in the P 2062 cell align with th...

Страница 4: ... Island NY 14072 0310 PHONE 716 773 7634 FAX 716 773 7744 EMAIL sales nrdllc com WEB www nrdllc com NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com INST2060 2 19 ...

Страница 5: ... the expired device to NRD for proper disposal Calibration is not required 3 0 Trouble Shooting Guide Symptom Probable Cause Corrective Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for ev...