background image

operates the indicator lights. The switch of autonomous operation on 

the mounting and the key of supply unit must be set into “I” position 

previously.

  

5.2.  Telescope  balancing  

For  smooth  motion of the telescope and  reliable operation  of the 

slow motion knob  it is important to balance its movable   parts on the 

axes of  the equatorial mounting.

For this purpose one should set  the telescope tube in the horizontal 

position, unscrew  the bolt of brake 6 (fig. 5) of the  declination axis   and 

holding slightly the tube by hand see to it  whether  it  remains  in the 

indifferent equilibrium. If the tube  is not  in balance, undo the screws  

of the clips which fix the tube and move  the tube along its axis until it 

will be in balance. After that one screw in the screws of the clips.

For balancing the telecope relative to the polar axis it is necessary 

to set the declination axis in the horizontal position.Then it is necesary 

to slacken each of three screws 2 through cap   of the watch drive  

(fig. 0). Holding the axis by hand see to it whether the telescope  is in 

balance about the polar axis. If the telescope is not in balance, move 

counterweight  8(fig.5) along the declination axis. After balancing tighten 

screws  2  of  the  friction  clutch  (fig.  0)  on  the  polar  axis  so  that  the 

telescope can not rotate easily.

The adjustment  of the friction clutch is considered to be finished if the 

telescope tube moves due to the minor effort  of the hand.

When mounting the various devices  on the telescope, for  example,   

a camera, it is required to balance the telescope additionally.

5.3. Precautionary measures

The  rate  of the  fuse  link mounted in the  supply unit must be  in 

compliance  with the  rate  denoted under the  fuse  link holder.

Mount the fuse link only after complete disconnection of the supply 

unit from  the  mains.

Connect the  bundled conductors to the  watch drive  and supply unit 

when the  supply unit is disconnected from  the  mains.

               

6

Содержание TAL -2

Страница 1: ...TELESCOPE 2 2 SERVICE MANUAL...

Страница 2: ...Operation with telescope 19 6 2 Photographic observations 21 6 3 Telescope and atmospheric conditions 22 7 Maintenance 23 8 Possible derangements and methods of their elimination 24 9 Rules of storage...

Страница 3: ...telescope is designed for visual observation of the celestial objects The telescope can operate normally at the ambient temperature from 30 C to minus 30 C When buying the telescope one should pay att...

Страница 4: ...cation 30x 1 12 47x 1 60x 0 29 95x 0 29 158x 0 17 317x 0 8 Resolution 1 Limiting magnitude 12m Range of slow motion control on the declination axes 4 Rotation of the telescope in right ascension 360 2...

Страница 5: ...s 1 Bracket 2 Control panel 1 Cable for car mains 1 Accessories and Parts Reticle 1 Barlow lens 1 Eyepiece of f 25 mm 1 Eyepiece of f 7 5 mm 1 Yellow light filter 1 Black light filter solar 1 Blue lig...

Страница 6: ...odies the optical units a primary mirror a diagonal mirror finderscope 3 fixed in the locating rings 4 eyepieces and Barlow lens which are inserted in focusing mechanism 1 The primarymirror fig 3 ismo...

Страница 7: ...2 bushing 3 finderscope 4 ring 5 telescope tube 6 equatorial mounting 7 pier 8 bundled conductors 9 supply unit 10 cord 11 supports 12 control panel Fig 1 General view of telescope withmetal pier 1 2...

Страница 8: ...Fig 2 General view of telescope withtripod 1 2 stops 3 objects table...

Страница 9: ...e declination axis is the saddle with hinged clips 1 in which the telescope tube is mounted fastened on the other end of the axis is the counterweights 5 which can move along the axis for balancing th...

Страница 10: ...micrometer screw of slow motion mechanism 3 declination axis 4 circle of declinations 5 counterweights 6 bolt 7 bracket with scale of latitudes 8 electric watch drive 9 handwheel of micrometer screw o...

Страница 11: ...tripod with the help of stops 1 and 2 Supply unit 9 fig 1 powers the watch drive tracking the celestial objects It is designed for 220 V 50 Hz 110V 60Hz mains and activated with the key If the contro...

Страница 12: ...12 Fig 6 Control Panel 1 indicator 2 speed selection buttons 3 correction buttons 4 lighting button 5 plug...

Страница 13: ...13 Fig 7 Optical train of telescope 1 primery mirror 2 eyepiece 3 diagonal mirror 4 finderscope...

Страница 14: ...14 Fig 8 Diagram of setting Barlow lens Eyepiece Barlow lens Eyepiece Focusing mount Focusing mount...

Страница 15: ...ps with the help of hinged screws The finderscope is mounted on the tube in two rings and fixed with six set screws available on the rings In transportation and storage a hole in the eyepiece tube is...

Страница 16: ...e declination axis in the horizontal position Then it is necesary to slacken each of three screws 12 through cap 11 of the watch drive fig 10 Holding the axis by hand see to it whether the telescope i...

Страница 17: ...Fig 9 Tools and accessories 1 solar screen 2 cap diaphragm 3 cap 4 Barlow lens 5 eyepieces 6 light filters 9 blind 10 reticle 11 adapter 17...

Страница 18: ...18 Fig 10 Watchdrive 1 worm gear wheel 2 cap 3 screw 4 handwheel 5 screw 6 screw 7 motor 8 screw 9 worm with gear wheel 10 worm wheel 11 cap 12 screw 13 cover 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 19: ...othed wheel of the worm takes place and secure them with screws 8 Mount cap 13 on the casing The smoothness of rotation of toothed wheel 1 together with the toothed wheel of worm 9 is checked by rotat...

Страница 20: ...n axis during operation of the watch mechanism it is required to set the telescope polar axis in parallel to the celestial axis In this case the northern upper end of the polar axis faces the celestia...

Страница 21: ...ope one brings the star or the planet to the centre of the field of view of the telescope at maximum magnification After that one sets the declination of the required star against the index The circle...

Страница 22: ...ial pole One should remember that if the polar axis is set incorrectly even in the case when the star image is kept on the cross hairs the images of the stars at the edges of the field of view appear...

Страница 23: ...the screws which fix the cell to the tube Without removing the mirror from the cell the mirror surface is wetted considerably with pure medical alcohol with the help of a cotton wool tampon By using...

Страница 24: ...y mirror The image of the diagonal mirror must be positioned precisely in the middle of the primary one The reflection of an observer s eye fig 11 must be seen at the centre of the diagonal mirror ref...

Страница 25: ...clear that the telescope is misadjusted and its mirrors and reflections from them are not concentric Fig 11 Setting concentricity of mirrors 1 inner diameter of focusing mount 2 diagonal mirror 3 ref...

Страница 26: ...o 40 C The impacts and sharp shaking should be avoided It is forbidden to store the telescope together with acids alkalies materials which liberate moisture or chemically active gases and vapours 10 A...

Страница 27: ...2 Bootes Boo 14h 42 8m 27 17 2 7 5 1 3 0 Bootes Dra 17h 04 3m 54 32 5 8 5 8 2 2 Draco Oph 18h 00 4m 08 11 5 4 6 0 2 0 Ophiucus 70 Oph 18h 02 9m 02 31 4 0 6 0 2 4 Ophiucus 1 Lyr 18h 42 7m 39 37 5 1 6 2...

Отзывы: