          Warning

Do not operate the unit near flammable fumes or gases such as the cabin of 
a gasoline power boat, or near propane tanks.

          Warning

Do not operate the unit in an enclosed area that contains automotive type 
lead-acid batteries. This type of battery emits explosive hydrogen gas which 
can be ignited by sparks.

          Warning

Always make all AC connections before making DC connections or the 
components built into the inverter can become energized producing an 
electrical shock hazard. Never work on the AC wiring without first physically 
disconnecting the DC connections.

          Warning

If connected with loads of over 1500W, two sets of same size wirings must be 
connected to the same one battery or the connected battery kit. And it may 
damage the inverter if using one set of wiring only or connecting two sets of 
wirings to different batteries separately!

          Caution

Do not connect the unit to live AC power circuits or there would be damage to 
the inverter. Do not connect any AC device which has its neutral conductor 
connected to ground to the unit.

          Warning

The case to the unit may become very warm under high power 
operationreaching 140°F(60°C). Be sure that there is at least 2 

(5cm) of 

unobstructed air space around the entire surface of the inverter at all times. 
During use, do not place materials that could be damaged by heat near the 
unit.

Содержание 4572002

Страница 1: ...ST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE 2000W Power Inverter...

Страница 2: ...CONTENTS 1 Introduction 2 Important Safety Information 3 Protective Features 4 Features 5 Installation 6 Operating Instructions 7 Troubleshooting 8 Specifications 9 Warranty 2 2 4 5 7 9 11 13 14...

Страница 3: ...low input voltage shut off low input voltage alarm low voltage turn off resume over heating shut off overload shut off short circuit protection The unit is not designed to be waterproof It applies to...

Страница 4: ...s Warning If connected with loads of over 1500W two sets of same size wirings must be connected to the same one battery or the connected battery kit And it may damage the inverter if using one set of...

Страница 5: ...also void the warranty Caution Some chargers for small nickel cadmium batteries can be damaged if connected to the unit Do not use the unit on the following items Small battery operated appliances su...

Страница 6: ...w the surrounding air temperature the inverter will automatically return to normal operation Overload Shut Off When the starting power exceeds the rated power the inverter will automatically shut down...

Страница 7: ...ble 4 Port for Remote Control Connect the remote control switch and press down the switch the remote control function acts remote control switch is not included 5 USB Port Offer 5V power to USB equipm...

Страница 8: ...minal Connect the black end of the DC power cord to Your 2000W Power Inverter supplies 2000 watts of max continuous power with 4000 watts of surge power When you turn on an appliance or a tool that op...

Страница 9: ...some metal jewelry such as rings bracelets and watches etc in case any accident would happen Connecting the inverter 1 Place the inverter on a flat surface such as on the vehicle floor 2 Please make s...

Страница 10: ...es that the inverter is powering When input voltage rose to 11 7V 12 3V DC inverter restores normal 9 6 Operating Instructions Caution A loose connection will cause the voltage to drop and may cause t...

Страница 11: ...erating temperature due to insufficient ventilation or a high temperature environment and the red LED indicator lights The cooling fan is designed with thermo controlled technology Caution Operating t...

Страница 12: ...ace battery Blown fuse Check and replace fuse Lose cable connections Check the connection to the battery Tighten as required AC products connected are rated at more than 2000W overload shutdown has oc...

Страница 13: ...er used to measure output voltage resulting in an apparent reading 5 to 15V too low Inverter s modified sine wave output requires true RMS voltmeter for accurate measurements Measured inverter output...

Страница 14: ...4 lb 3370g AC output frequency nominal 58 62Hz AC output waveform Modified sine wave AC output frequency nominal 5 V DC DC input voltage range 12 8 13 2V DC 1A at a 12V input Low battery alarm trigge...

Страница 15: ...damaged or altered either internally or externally or damaged from improper use NPower will repair or replace the defective product free of charge Proof of purchase may be required Warranty term is no...