background image

PWR-03D User Manual 

___________________________________________________________________________ 

___________________________________________________________________________ 
version 1.0 

page 3 

2.  PWR-03D  

2.1. 

PWR-03D 

The external power supply PWR-03D is  capable  of driving up to 3  EPMS-E housings or  an 
EXT-16DX amplifier with R/I-T1DX. Each housing is connected by a 6-pole cable from one 
of  three  connectors  on  the  front  panel  of  the  PWR-03D  to  the  rear  panel  of  the  respective 
EPMS-E  or  EXT-16DX  /  R/I-T1DX  housing  (see  Figure  1,  Figure  3).  A  POWER  LED 
indicates that the PWR-03D is powered on (see Figure 1). Power switch, voltage selector and 
fuse are located at the rear panel (see Figure 2).  
 
Note: The chassis of the PWR-03D is connected to protective earth, and it provides protective 
earth to the EPMS-E housing if connected. 

 

 

 

 

Figure 1: PWR-03D front panel view 

Figure 2: PWR-03D rear panel view 

 
Note: This power supply is intended to be used with npi EPMS-E or EXT-16DX / R/I-T1DX 
systems only. 

 

 

2.2. 

System Grounding 

EPMS-E-07 (EXT-16DX) 

The 19" cabinet is connected to the CHASSIS connector at the rear panel. It 
can be connected to the SYSTEM GROUND (GND) on the rear panel of the 
instrument (see Figure 3). Without this connection, the EPMS chassis and the 
chassis of all modules plugged in is free floating.  

 
 
Note:  The  EPMS-E-07  /  EXT-16DX  chassis  is  not 
connected to protective earth. 
 
Important:  Always  adhere  to  the  appropriate  safety 
measures.  
 
 

Figure 3: Rear panel connectors of the EPMS-E-07 (left) and EXT-16DX (right).  

2.3. 

Technical Data 

PWR-03D 

Input:    

115/230 V AC, 60/50 Hz, fuse 1.6/0.8 A, slow 

Dimensions:  (W x D x H) 225 mm x 210 mm x 85 mm 

 