background image

AFL Telecommunications

NOYES

www.noyes-fi ber.com

MLP 4-2 Fiber Optic

 

Loss Test Kit

 

Loss Measurements at 850 and 1300 nm

 

Multimode and Singlemode Testing

 

Set Reference for Each Wavelength

 

Small Size, Field Portable, Battery Operated

 

Auto or Manual Power Off

 

N.I.S.T. Traceable

Description

The MLP 4-2 Test Kit offers accurate fi ber optic testing at an 
affordable price. Combining the OPM 4-2C Optical Power 
Meter and the OLS 1-2 Optical Light Source in a rugged 
carry case, the MLP 4-2 is a complete Test Kit for fi ber 
optic LAN's, and WAN's.

Used during installations or maintenance, the MLP 4-2 
performs insertion loss measurements on multimode fi ber 
at 850 and 1300nm, as well as singlemode fi ber at 1300nm. 
The  auto  zero  feature  stores  reference  values  at  each 
wavelength for direct loss readings in dB. 

1   Attach Mandrel to Transmit Jumper

Wrap the transmit jumper fi ve times around the mandrel and attach 
it to the output port of the OLS 1 (LED source).

Note: The transmit and receive jumpers must use same fi ber type 
(50 or 62.5

µ

m) as link.

2   Set Reference (One Jumper Method) 

Connect the output of the OLS 1 directly to the input of the OPM 4 
(optical power meter). Then press and hold the Ref (set reference) 
key until the word “HELD” appears. When you release the Ref 
key, the OPM 4 should display “0 dB” (+/- 0.05 dB) indicating 
that the power measured at output of the transmit jumper has 
been recorded as the reference level for your insertion loss 
measurements.  

3   Check Jumpers

Disconnect the transmit jumper from the OPM 4 (be sure NOT to 
remove the end of the jumper connected to the OLS 1). Attach the 
receive jumper to the OPM 4. Mate the free ends of the transmit 
and receive jumpers. Verify that the insertion loss of this mated 
connector pair is well under 0.75 dB, the maximum allowed by 
the TIA. Noyes recommends that the loss of your mated test 
jumpers be < 0.4 dB. If not, clean both jumpers and repeat 
steps 2 and 3.   

4     Test  Links

Connect the OLS 1 and OPM 4 to opposite ends of each link to be 
tested. Take insertion loss measurements.

Multimode Fiber Link Insertion Loss Testing

3.2 dB

Transmit 
Jumper

Link under test

Receive 
Jumper

OLS 1

OPM 4

OLS 1

OPM 4

Transmit 
Jumper

Mandrel 
Wrap

Adapter

Receive 
Jumper

0.4 dB

OLS 1

OPM 4

Transmit 
Jumper

Mandrel 
Wrap

0 dB

Mandrel 

Transmit Jumper 
(same core size, 50 
or 62.5

µ

m, as link)

5 wraps

1

2

3

4

Отзывы: