Test Result 4:
Wiring diagram (WIREMAP) display
when there is an open circuit at the far-end of cable.
Wire map:fail
M: 12345678
Iiiiiiii
R: 12 x45 x78 id1
"
R:" line "3" and "6" pins location display "x", it indicates an open circuit
in far-end plug "3" and "6" pins and the open circuit is located nearby the
far-end plug.(The open point should be at the 10% cable length)
because
error at the far-end always displays in pair as above.,which means there
is one open circuit or both
are open in the far-end"3"and "6"pins.
Test Result 5:
Wiring diagram (WIREMAP) display when
there is an open circuit at the near-end of cable.
It will display wiring diagram (WIREMAP) as follows if there is an open
circuit at the near-end plug of the cable:
Wire map:fail
M: 12 x45678
Iiiiiiii
R: 12345678 id1
"
M:" line "3" pin location displays "x", it indicates an open circuit at
near-end plug "3" pin and the open circuit is located nearby the near-
end plug.(The open circuit should be located within 10% cable length
if it is measured from the near-end plug)
Test Result 6:
Wiring diagram (WIREMAP) display when
there is an open circuit in the middle of the cable.
It will display wiring diagram (WIREMAP) as follows if there is an
open circuit in the middle of the cable:
Wire map:fail
M: 12345678
Iixiiiii
R: 12345678 id1
"|" line "3" pin location displays "x", it indicates an open circuit in the
middle of "3" pin cable. (The open circuit should be located within
10%-90%cable length if it is measured from the near-end plug.) as
detailed hereinafter.
Your excellent helper in cable test!
07
Pair and length measurement (PAIR & LENGTH) function:
When testing cable length, just connect one end of cable with
Main tester, no need of remote unit.
After entering into “PAIR & LENGTH” function, it will display as follows to
indicate the measurement is being undertaken:
----
Testing
----
12345678...
Note:In view of different technical parameters in various brand cables,
the user should calibrate the cable length before length measurement
(Refer to the details herein).
Test Result 1: Short circuit (SHORT)
It will display as follows if there is any short circuit in cable or terminal:
(12 short circuit in the sample)
Short:
12
Test Result 2:
Normal pair and length (PAIR &LENGTH) display
P a i r 12 100.0m
P a i r 78 99.8m
P a i r 36 100.3m
P a i r 45 100.2m
return the main menu.
It will display as follows if pair and length(PAIR & LENGTH)
measurement is in normal condition:
PAIR&L
Your excellent helper in cable test!
08