4.Specification

Model

NF-271

NF-272L

100m

80m

60m

70m

50m

Range

Acuuracy

LCD screen

Wavelength & Output

Working temperature

Storage termperature

Laser Off

Auto-off

Protecion level

Power

Voice broadcast

Degree measurement

Level measurement

Unit switching

Benchmark switching

Single measurement

Continuous 

measurement

Area measurement

Volume measurement

Pythagorean 
measurement

Addition & subtraction 
measurement

Size

Weight

+/-

1.5 mm

FSNT with backlight

620~680nm, <1mw

0~40

-

20~60

30s

2minutes

IP54

AAA

850mAh Lithlium 

battery

×

×

×

m/ft/in/ft+in

Vertical measurment

Data storage

×

×

50 sets

99 sets

119*50*26mm

100g

3.14

Setting

Press"

        " 

2s to go in, the flashing arrow 

on the screen indicates that the Buzzer/Voice 

broadcast switch setting has been entered. 

By press "            " or "             " to adjust the 

Off/On. Then press "              " to go volice 

calibration setting, by press "          " or "          " 

adjust the parameters. Press "

      " 

to quit.

+

-

+

-

CLEAR

Buzzer/Voice broadcast

Switch 

Calibration

Value

3.13

Unit switching

Press "

      " 

to go in, you can query the 

datas measured before. Then press "           " 

or "

       " 

to quit.

CLEAR

Содержание NF-271

Страница 1: ...UAL Your excellent helper in laser distance test NEW Laser Distance Meter Laser Distance Meter Laser Distance Meter Laser Distance Meter Laser Distance Meter Laser Distance Meter VER V1 Your excellent...

Страница 2: ...he plane or around medical equipment don t use it in inflammable explosive environment Discarded batteries or meter device shall not process just like household garbage please handle them in line with...

Страница 3: ...functions such as Level measurement Vertical measurement Voice broadcast Degree measurement and so on 4 5 6 7 1 2 3 1 2 3 4 5 6 7 Add Subtract Power Clear Measure Menu Benchmark Unit switch Record que...

Страница 4: ...orean measurement Secondary Pythagorean measurement Level measurement Vertical measurement NF 272L 3 Operation instructions 3 1 Turn on o Long press 2s to turn on Long press 2s to turn o 3 2 Single me...

Страница 5: ...get the values it will work out the height L on the screen L 3 7 Secondary Pythagorean measurement Press to go in when the testeing mode in Pythagorean measurement then press to get the values it wil...

Страница 6: ...000m 0 00m 0 00ft 0 00 0 0in 0 in 3 12 Benchmark switching Press to go in you can set the benchmark to measure from the front side or from the end side 3 8 Level measurement Pres to go in when the te...

Страница 7: ...measurement Addition subtraction measurement Size Weight 1 5 mm FSNT with backlight 620 680nm 1mw 0 40 20 60 30s 2minutes IP54 AAA 850mAh Lithlium battery m ft in ft in Vertical measurment Data stora...

Страница 8: ...1pcs 1pcs 1 2 3 4 5 6 7 6 Error reasons and solutions Reason High or low temperature Low battery Wrong calculate Weak signal Solution Measure at the required temperature range Replace new battery Mea...

Отзывы: