![Novusun CNC NVBDH+ Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/novusun-cnc/nvbdh/nvbdh_manual_1713375018.webp)
5
A
increase parameter
parameter uppage or increase parameter
6
speed
control
Motor speed adjust,CW increase speed,CCW reduce
potentiometer
speed.
7
LED display
display parameter or motor running speed.
Chart 3-1 Control panel definition
3.2 Parameter setting and LED display
1 •. When power on buzzer “DI--”rings one time,and LED lights up, driver
standby.
.
.
.
.
2^ At the status of Standby,keep pressing S button and enter into parameter setting page,kilobit
displayed P,hundreds place is flashing,then press
A
or
L
to increase or reduce your
parameter. The adjustable range is from P0 to P5,and Po is exit.
3 When selected the parameter,keep pressing S button and enter into parameter setting,then
kilobit on the page displayed P, hundreds place is flashing,decade displayed “-”,the unit
flashing and shows the value.
P 1-0
4^ After parameter setting,keep pressing S button and confirm the setting,page go to last menu.
P 1
5^ When all the parameter setting finished,at the first menu,press
A
or
L
to select Po,
And keep pressing S,Then exit this page,into standby status.
.
.
.
.
6^ At the first setting menu or the second setting menu,if without any operation over 15
seconds,system will exit from the setting display,and enter into standby status.