Novus TxIsoPack Скачать руководство пользователя страница 3

NOVUS AUTOMATION 

3/3 

 

PT100 3-WIRES 

 

Fig. 6 – Transmitter electrical connections (Pt100 3-wires) 

PT100 4-WIRES 

 

Fig. 7 – Transmitter electrical connections (Pt100 4-wires) 

THERMOCOUPLES 

 

Fig. 8 – Transmitter electrical connections (Thermocouple) 

VOLTAGE (0-50 mV) 

 

Fig. 9 – Transmitter electrical connections (0-50 mV) 

OPERATION 

The transmitter is perfectly factory-calibrated with standardized sensors, not 

requiring any adjustment by the user. 
The sensor offset can be also changed through the TxConfig software. The 

USB connection can be made even with the transmitter connected to the 

process and operating without causing errors in the measurement. See item 

Zero Correction in the chapter CONFIGURATION of this guideline. 
The uer must choose the most suitable sensor and range to the process. The 

chosen range must not exceed the maximum range of measurement defined 

for the sensor and should not be smaller than the minimum range for the 

same sensor. 
It is important to note that the accuracy of the transmitter is always based on 

the maximum range of the sensor used, even when a mid-range was set. 

Example: 

 

The sensor Pt100 has a max. range of –200 to +650 °C and total 

accuracy of 0.2 %, thus we can have an absolute error up to 1.7 °C ( 

0.2 % of 850 °C). 

 

The absolute error is the same for a wide range as the maximum (-

200 to 650 ° C), to a narrower band User-defined. (For example: 0 to 

100 °C.) 

Note:  When measurements are made at the transmitter, see if the Pt100 

excitation current required by the calibrator is compatible with the Pt100 

excitation current used in the transmitter: 0.17 mA. 

SAFETY INFORMATION 

Any control system design should take into account that any part of the 

system has the potential to fail. This product is not a protection or safety 

device and its alarms are not intended to protect against product failures. 

Independent safety devices should be always provided if personnel or 

property are at risk. 
Product performance and specifications may be affected by its environment 

and installation. It’s user’s responsibility to assure proper grounding, 

shielding, cable routing and electrical noise filtering, in accordance with local 

regulations, EMC standards and good installation practices. 

SUPPORT AND MAINTENANCE 

This product contains no serviceable parts inside. Contact our local 

distributor in case you need authorized service. For troubleshooting, visit our 

FAQ at 

www.novusautomation.com

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

NOVUS warrants to the original purchaser that this product is free from 

defects in material and workmanship under normal use and service within 

one (1) year from the date of shipment from factory or from its official sales 

channel to the original purchaser. 

NOVUS liability under this warranty shall not in any case exceed the cost of 

correcting defects in the product or of supplying replacement product as 

herein provided and upon the expiration of the warranty period all such 

liability shall terminate. 

For complete information on warranty and liability limitations, check 

appropriate section in our web site: 

www.novusautomation.com/warranty

 

Отзывы: