MOST FREQUENTLY FOUND PROBLEMS 

The LED is not flashing: The LED flashing light is intentionally 

weak, and it can be difficult to see it in clear environments, certify it is 

really not flashing. 
Communication with the equipment fails: 
Make sure the COM port is selected correctly and there is no other 

program using the same port during communication attempts; 
Make sure there is no physical obstacle blocking the infrared signal; 
Make sure the port selected does not present any problem. 

7

 

SPECIAL CARE 

When handling the device and its battery, observe the following: 
To achieve the IP67 protection degree the cover of TagTemp Stick 

should always be kept properly closed. 

8

 

WARRANTY 

Warranty conditions are available on our web site 

www.novusautomation.com/warranty

Содержание TagTemp Stick

Страница 1: ...memory 2 TECHNICAL DATA Measure Range Temperature 20 0 C to 70 0 C Accuracy 0 5 C 25 ºC 1 C max along the entire measured range Note A measure error can be fixed using the OFFSET parameter in the LogChart II software Measurement response time 90 10 min in air Measurement Resolutions Temperature 0 1 C Memory capacity 32 000 32 k logs Measurement Interval 5 seconds min 18 hours max Supply 3 0 V lith...

Страница 2: ...nformation Area with information about the equipment such as Model Serial Number equipment Date Time PC Date Time firmware version memory capacity and number of acquisitions stored in memory In this field time is constantly updated while the communication between equipment and computer is taking place 3 Readings Presents a series of parameters that define the acquisition process Interval Defines t...

Страница 3: ...Resume button action sends the appropriate command depending on the current registration status If the records are In Progress and pressing this button it will be send a command to Pause the records Pause Pauses the registry allowing it to be resumed later using the Resume button If registration is Paused and pressing this button it will be send a command to Resume the records Resume Resumes the r...

Страница 4: ...equipment whose data were just read and its configuration The screen can be displayed by pressing the icon Parameter Viewing Fig 08 General information window 5 3 EXPORTING DATA Logged data can be exported to different file formats for further analysis To export access File Export or click the icon 5 4 EXPORTING THE DATA REGISTERED Battery Level Indicates the level of battery voltage Device Status...

Страница 5: ...ected correctly and there is no other program using the same port during communication attempts Make sure there is no physical obstacle blocking the infrared signal Make sure the port selected does not present any problem 7 SPECIAL CARE When handling the device and its battery observe the following To achieve the IP67 protection degree the cover of TagTemp Stick should always be kept properly clos...

Отзывы: