OfficeLight Corona
9 / 40
8 / 40
GB
Contents
�. General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . �
1.1. Declaration of Conformity . . . . . . . . . . . . . . . . . .2
1.2. Technical specifications/Special functions. 8
1.3. Safety precautions. . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4. Pictogram legend . . . . . . . . . . . . . . . . . . . . . . . . . .9
1.5. Dimensions/Swivelling range. . . . . . . . . . . . . 34
1.6. Shade dimensions . . . . . . . . . . . . . . . . . . . . . . . . 34
�. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . ��
2.1. Package contents . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.2. Installing universal clamp I . . . . . . . . . . . . . . . 36
2.3. Installing OfficeLight Corona . . . . . . . . . . . . . 36
2.4. Plugging in power supply unit. . . . . . . . . . . . 3�
2.5. Switch functions. . . . . . . . . . . . . . . . . . . . . . . . . . 3�
2.6. Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
�.
Possible combinations
. . . . . . . . . . . . . . . . . . . . 39
We reserve the right to make technical modifications and improvements in the interest of advancing our products.
1.
1.4.
Pictogram legend
1.
Translation of the original operating instructions
Read user information/
safety precautions
Important information
ATTENTION
Disconnect device from power
supply
Connect device to power supply
Maintenance information /
troubleshooting
Action radius
Universal clamp 1
Conformity with applicable EU
safety directives
TÜV Nord certifies that the prod-
uct complies with the German
Equipment and Product Safety
Act .
Protection class II (double insula-
tion, no earthed plug required.)
ON
Light on
MAX
Maximum light output
Briefly press switch
Keep switch pressed;
dimming function
Multi-function switch flashing
1.3.
Safety precautions
• Risk of blinding and injury! Never look directly into the light source.
• Protect the light from knocks and impacts, moisture and excessive heat.
Never stand the light on radiators or in the sun.
• Do not use the light near water-filled containers.
• Tripping hazard! Make sure the power cord does not present a hazard.
Do not wind the power cord around the light.
1.2.
• Mains voltage/frequency:
100-240V / 50-60Hz
• Power cord:
Cable 2 m long, 2-core (2 x 0.5 mm
2
)
CEE �/16 plug, power socket type EF
• Temperature range:
-10°C to 40°C
• IP rating:
IP20
•
The office light switches off automatically
if the multi-function switch is left unpressed
for 10 hours.
•
The light automatically switches to minimum
output if it overheats while operating. This is
shown by the multi-function switch flashing.
Technical specifications/Special functions