![Novus NVIP-3DN7000V/IRH-2P Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/novus/nvip-3dn7000v-irh-2p/nvip-3dn7000v-irh-2p_user-manual_1713155020.webp)
NVIP-3DN7000V/IRH-2P User’s manual (short form) ver.1.0
All rights reserved © AAT Holding sp. z o.o.
20
5. ELECTRIC CONNECTORS AND ACCESORIES
5.1. Connecting power supply to the camera.
The camera is supplied by using RJ45 network socket. To run NOVUS IP camera you have to connect
ethernet cable between camera and network switch with PoE support (IEEE 802.3af). You can also use
a power injector compatible with IEEE 802.3af standard.
Information: Power supply adapter is not included.
Caution:
If the camera power via PoE heater and fan will not work. Fun and heater work only with
external power supply connected to power socket “5”.
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge
protectors is advised. Any damages resulting from surges are not eligible for service repairs.
5.2. Connecting alarm inputs/outputs.
Description of alarm input/output connector terminal is presented in the table below:
Input and output connector states:
Alarm input connections
ELECTRIC CONNECTORS AND ACCESORIES
Alarm
input -
IP Camera
Alarm
input +
Switch/sensor
Alarm input
Normal state
5V
-
Active state
0V
I<0,2mA
Alarm output
Normal state
No connected (R=∞)
-
Active state
Conected (R=30
Ω
)
0.1A, 30VDC/AC
Cable
Description
Color
Alarm input +
GREEN
Alarm input -
ALM_IN -
BLUE
Alarm
A
ORANGE
Alarm output -
ALM_OUT -
YELLOW