NVIP-3DN5030SD/IRH-2 User’s manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
19
2. Video Parameter
Stream
- Stream ID (choose one from available streams)
Bite Rate Type
- Information about bit rate type
Bit Rate (kbps)
- Information about bit rate
I Frame Interval
- Information about I frame interval
Quality
- Information about quality
USE TIME STAMP - Video buffer (increases delay when enabled, maximum delay is 5s)
NOTICE:
USE TIME STAMP
function will not be available when using Flash instead of ActiveX.
3. PTZ Control Panel
PTZ Configure:
Preset
- Programming, deleting, and recalling presets
Track
- Programming, deleting, and recalling tracks
Speed
- Setting speed of movement
3D Position
- Turns on/off control using the mouse
North
- Setting orientation of the camera
Timer
- Setting schedules
PTZ Control:
Arrow keys
- Controlling the movement of the camera: up/down, right/left
„Home” key
- Function unavailable
Zoom
- Zoom control
Focus
- Focus control
Iris
- Function unavailable
Brush
- Function unavailable
On/Off IR
-
Function unavailable
4. Menu bar
Change Password
- Change users password
NOTICE: Default password "pass" can be restored only after restoring default settings of the camera)
Sign Out
- Log out from camera
5. Video Control
Camera
- Default number of the camera is 1.
Video
- Turn on/off video
Audio
- Turn on/off audio
ELECTRIC CONNECTORS AND ACCESORIES
5. ELECTRIC CONNECTORS AND ACCESORIES
5.1. Connecting power supply to the camera.
Camera can be supplied using external power supply unit corresponding with the camera parameters.
When selecting the power supply should also be take into account the power consumption of the heater.
CAUTION!
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge
protectors is advised. Any damages resulting from surges are not eligible for service repairs.
6. RESTORING FACTORY DEFAULTS
NOVUS NVIP-3DN5030SD/IRH-2 camera allow to restore defaults via www menu.
6.1.
Software restoration of factory settings the IP camera
User can restore default settings of the IP camera included the network settings (optional). To restore to
default settings go to:
Maintenance -> Device Restart
tab. Process of restoring takes about two
minutes.