Wideo domofony Novus
–
instrukcja instalacji modułu windowego
NVE-ELV200
Video intercom Novus
–
Installation manual elevator controller NVE-ELV200
AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
Wszelkie prawa zastrzeżone
. All rights reserved
43
Set the device IP address;
Set the subnet mask and gateway;
Input the server IP address(the IP address of first door panel)
3) Set the Activation information
Set the Operation mode to “2” (Advanced mode)
Set the Relay mode
: 0 is normally open, 1 is normally closed.
Set the Delay request
: the response time between two lift request instructions.
It supports to set between 100 milliseconds and 5000 milliseconds, and the default is 1000
milliseconds.
Set the Activation time
: Time during which relay remains closed.
It supports to set between 100 milliseconds and 5000 milliseconds, and the default is 500
milliseconds.
Set the Delay time
: the interval between two relays in an instruction.
It supports to set between 100 milliseconds and 5000 milliseconds, and the default is 500
milliseconds.
4) After set the information, please click the “Apply” button to register, and then it will restart.
7.2.3
Set the floor number of door panel
After configure the controller to the system, it also needs to set the floor number of door panel.
Please click the “Address Book Config” item in web client of the first door panel, and click each
building panel to set floor number in “Floor No:” as the following picture shown.