5. SETTINGS
5.1. Connecting NV-IR60/150LED IR illuminators
NV-IR60/150LED IR illuminator can cooperate with other illuminators of the same type.
After connecting the outoput (LED Output) of master device with signal input (LED Input) of another
device, master iluminator will control the rest of connected devices.
It is sufficient to set the right
level of IR LED intensity and the visible light sensor sensitivity for only one (master) device.
LED Output states:
IR LED on
=> DC 0V
IR LED off
=> DC 3V-3.3V
LED Input states:
DC 0V
=> IR LED on
DC 3V-7.5V
=> IR LED off
5.2. Adjusting the intensity of IR LED
If want to change the intensity of the IR light, open the cover at the back of the iluminator
(Current socket) and adjust the value of this parameter by using a screwdriver.
5.3. Adjusting the sensitivity of visible light sensor
If want to change the sensitivity of visible light sensor, open the cover at the back of the ilu-
minator (Lux socket) and adjust the value of this parameter by using a screwdriver. Increasing this
parameter will cause the IR LED will start working under the darker situation. Decreasing this para-
meter will cause the IR LED will start working under the brighter situation.