Novus NV-116S/P+ Скачать руководство пользователя страница 2

NV

-

116S/P+ , NV

-

124S/P+ ,User

s manual ver. 1.0

 

All rights reserved © AAT Holding S.A. 

 

 

2

 

EMC (2004/108/EC) and LVD (2006/95/EC ) Directives

 

 
 

CE Marking

 

 

Our products are manufactured to comply with the requirements of the following directives and national 

regulations implementing the directives: 

 

 

 

Electromagnetic compatibility EMC 2004/108/EC.

 

 

Low  voltage  LVD  2006/95/EC  with  further  amendment.  The  Directive  applies  to  electrical 

equipment  designed  for  use  with  a  voltage  rating  of  between  50VAC  and  1000VAC  as  well  as 

75VDC and 1500VDC.

 

 

WEEE Directive 2002/96/EC

 

 

 

Information on Disposal for Users of Waste Electrical and Electronic Equipment

 

 

 

This  appliance  is  marked  according  to  the  European  1000VAC  Directive  on  Waste  Electrical  and  Electronic 

Equipment (2002/96/EC) and further amendments. By ensuring this product is disposed of correctly, you 

will help to prevent potential negative consequences for the environment and human health, which could 

otherwise be caused by inappropriate waste handling of this product.

 

The symbol on the product, or the documents accompanying the product, indicates that this appliance may 

not be treated as household waste. It shall be handed over to the applicable collection point for used up electrical 

and  electronic  equipment  for  recycling  purpose.  For  more  information  about  recycling  of  this  product,  please 

contact  your  local  authorities,  your  household  waste  disposal  service  or  the  shop  where  you  purchased  the 

product.

 

 

 

 

 

RoHS Directive 2002/95/EC

 

 

Out  of  concern  for  human  health  protection  and  friendly  environment,  we  assure  that  our  products 

falling under RoHS Directive regulations, regarding the restriction of the use of hazardous substances 

in electrical and electronic equipment, have been designed and manufactured in compliance with the 

above mentioned regulations. Simultaneously, we claim that our products have been tested and do not 

contain  hazardous substances  whose  exceeding  limits  could  have  negative  impact  on human  health  or  natural 

environment.

 

 

 

Information

 

 

The device, as a part of professional CCTV system used for surveillance and control, is not designed for self 

installation in households by individuals without technical knowledge.

 

 

The  manufacturer  is  not  responsible  for  defects  and  damages  that  result  from  improper  or  inconsistent  with 

user

s manual installation of the device in the system.

 

 

 

INFORMATION

 

Содержание NV-116S/P+

Страница 1: ...User s manual NV 116S P NV 124S P ...

Страница 2: ...icates that this appliance may not be treated as household waste It shall be handed over to the applicable collection point for used up electrical and electronic equipment for recycling purpose For more information about recycling of this product please contact your local authorities your household waste disposal service or the shop where you purchased the product RoHS Directive 2002 95 EC Out of ...

Страница 3: ...owing manual and read all the safety and operating instructions before starting the device 2 Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary 3 All the safety precautions referred to in this manual should be strictly followed as they have a direct influence on user s safety and durability and reliability of the device 4 All action...

Страница 4: ...3 Unplug the switch from the power source immediately and contact the proper maintenance department when the following occurs Damages to the power cord or to the plug itself Liquids getting inside the device or exposure to strong mechanical shock Device behaves in a way not described in the manual and all adjustments approved by the manufacturer and possible to apply by user himself seem not to ha...

Страница 5: ...f at standards can provide 30W power supply e g for camera with infrared or heater Provide 2 UPLINK ports 2 x 1000Mbps optical fiber port SFP and 2 x 1000Mbps ethernet port UPLINK ethernet port can be connected conveniently to NVR and other high bandwidth device with distance up to 150 m UPLINK optical port SFP is designed for SFP optical fiber modules solving problem of long distance transmission...

Страница 6: ...andards can provide 30W power supply e g for camera with infrared or heater Provide 2 UPLINK ports 2 x 1000Mbps optical fiber port SFP and 2 x 1000Mbps ethernet port UPLINK ethernet port can be connected conveniently to NVR and other high bandwidth device with distance up to 150 m UPLINK optical port SFP is designed for SFP optical fiber modules solving problem of long distance transmission Fast a...

Страница 7: ... 150m Port UPLINK Ethernet max 150m PoE 1 16 20m PoE 1 16 max 150m PoE Protocol IEEE802 3 af IEEE802 3 at Network Standard IEEE802 3 10BASE T IEEE802 3u 100BASE TX IEEE802 3ab 1000BASE T IEEE802 3z 1000BASE SX LX FUNCTIONS Key Button 1 switch reset button Surge Protection yes INSTALLATION PARAMETERS Dimensions mm 315 W x 44 H x 442 D Weight 3 54kg Power Supply 230V Power Consumption 320W Power Efi...

Страница 8: ...x 150m Port UPLINK Ethernet max 150m PoE 1 24 20m PoE 1 24 max 150m PoE Protocol IEEE802 3 af IEEE802 3 at Network Standard IEEE802 3 10BASE T IEEE802 3u 100BASE TX IEEE802 3ab 1000BASE T IEEE802 3z 1000BASE SX LX FUNCTIONS Key Button 1 switch reset button Surge protection yes INSTALLATION PARAMETERS Dimensions mm 315 W x 44 H x 442 D Weight 3 73kg Power Supply 230V Power Consumption 420W Power Ef...

Страница 9: ...ENTS 4 POSITION AND FUNCTIONS OF NV 116S P SWICH COMPONENTS A Ethernet 10 100 1 16 Ports B UPLINK Ethernet 10 100 1000 Port C UPLINK SFP 10 100 1000 Port D Console Port E Reset button F Ethernet PoE ports LED indicators G UPLINK ports LED indicators H Power indicator I Power supply 100 240V Front A B C D E F G H I Back ...

Страница 10: ...ENTS 4 1 POSITION AND FUNCTIONS OF NV 124S P SWICH COMPONENTS A Ethernet 10 100 1 24 Ports B UPLINK Ethernet 10 100 1000 Port C UPLINK SFP 10 100 1000 Port D Console Port E Reset button F Ethernet PoE ports LED indicators G UPLINK ports LED indicators H Power indicator I Power supply 100 240V A B C D E F G H I Front Back ...

Страница 11: ... browser Device IP address is 192 168 1 200 login and password is admin admin It is required to set computer IP address in the same IP address group address as switch due to lack of DHCP server function 5 1 In the SYSTEM STATUS user can change time zone NTP server or edit switch information Time zone Server NTP Information data Hardware information ...

Страница 12: ...d disable or enable the port In Speed limit tab user can limit the bandwidth for individual ports or for the group of ports 5 3 PoE tab is a set of helpful features for PoE ports configuration and budget management We can set power limits for single ports or for group of ports Priority settings allow to choose camera to switch off in case of excessive power demand ...

Страница 13: ...pful in cases where there are too many devices working in network VLAN functions allow to separate workstation computers from cameras or servers 5 5 QoS tab allows to set ports speed priorities WARNING By default all switch ports are in VLAN 1 to make changes in the switch user must be connected to the port VLAN 1 ...

Страница 14: ... TRUNK tab allows to connect switches using multiple ports without loop error risk User gains multiple speed ports E g if user uses three ports he gains 300Mbps Scheme below presents the implementation SWITCH MANAGEMENT WARNING In this implementation TRUNK does not guarantee redundancy ...

Страница 15: ...ANAGEMENT tab allows to manage SNMP events The switch supports three versions V1 V2 V3 5 8 NETWORK STATISTICS tab allows to monitor FLOW STATISTICS tab and MAC table 5 8 1 FLOW STATISTICS tab allows to check the status of transmitted packets 5 8 2 MAC table allows to check the MAC address connected to the switch ...

Страница 16: ...rights reserved AAT Holding S A 16 SWITCH MANAGEMENT 5 9 SYSTEM MANAGEMENT tab allows to change switch IP address settings user accounts update software or to view logs 5 9 1 IP address settings 5 9 2 User settings 5 9 3 Logs 5 9 4 The File Manager ...

Страница 17: ...NV 116S P NV 124S P User s manual ver 1 0 All rights reserved AAT Holding S A 17 NOTES ...

Страница 18: ...P NV 124S P User s manual ver 1 0 All rights reserved AAT Holding S A 18 AAT Holding sp z o o ul Puławska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com 2015 07 23 wer 1 0 TW MK ...

Страница 19: ...NV 116S P NV 124S P Instrukcja obsługi ...

Страница 20: ...domowego Urządzenie należy oddać do odpowiedniego punktu utylizacji odpadów w celu recyklingu Aby uzyskać dodatkowe informacje dotyczące recyklingu niniejszego produktu należy skontaktować się z przedstawicielem władz lokalnych dostawcą usług utylizacji odpadów lub sklepem gdzie nabyto produkt Dyrektywa RoHS 2002 95 EC Informacja dla użytkowników dotycząca ograniczenia użycia substancji niebezpiec...

Страница 21: ... instalatorów i użytkowników muszą być realizowane zgodnie z opisem zawartym w instrukcji 5 W czasie czynności konserwatorskich urządzenie musi być odłączone od zasilania 6 Nie wolno stosować żadnych dodatkowych urządzeń lub podzespołów nie przewidzianych i nie zalecanych przez producenta 7 Nie należy instalować tego urządzenia w miejscu gdzie nie można zapewnić właściwej wentylacji np zamknięte s...

Страница 22: ...ypadkach Uszkodzenia przewodu zasilającego lub wtyczki tego przewodu Przedostania się cieczy do środka urządzenia lub gdy zostało ono narażone na silny uraz mechaniczny Urządzenie działa w sposób odbiegający od opisanego w instrukcji a regulacje dopuszczone przez producenta i możliwe do samodzielnego przeprowadzenia przez użytkownika nie przynoszą spodziewanych rezultatów Obudowa została uszkodzon...

Страница 23: ... zagwarantować 30W zapotrzebowania dla kamer o dużym zużyciu energii takich jak kamer z podczerwienią czy grzałką 2 porty UPLINK 2x 1000Mb s port optyczny SFP i 2x 1000Mb s Ethernet port Do portu UPLINK Ethernet można podłączyć NVR albo inne urządzenia wymagające wyższego transferu z zasięgiem transmisji do 150m UPLINK optyczny zarezerwowany jest dla modułów światłowodowych SFP dzięki którym zapew...

Страница 24: ... zagwarantować 30W zapotrzebowania dla kamer o dużym zużyciu energii takich jak kamer z podczerwienią czy grzałką 2 porty UPLINK 2x 1000Mb s port optyczny SFP i 2x 1000Mb s Ethernet port Do portu UPLINK Ethernet można podłączyć NVR albo inne urządzenia wymagające wyższego transferu z zasięgiem transmisji do 150m UPLINK optyczny zarezerwowany jest dla modułów światłowodowych SFP dzięki którym zapew...

Страница 25: ...150m PoE 1 16 20m PoE 1 16 Max150m Standardy PoE IEEE802 3 af IEEE802 3 at Obsługiwane protokoły IEEE802 3 10BASE T IEEE802 3u 100BASE TX IEEE802 3ab 1000BASE T IEEE802 3z 1000BASE SX LX FUNKCJE Przyciski 1 przycisk reset dla całego urządzenia Zabezpieczenie przeciwprzepięciowe tak PARAMETRY INSTALACYJNE Wymiary mm 315 szer x 442 gł x 44 wys Masa 3 54kg Zasilanie 230V Pobór mocy urządzenia 320W Wy...

Страница 26: ... 150m PoE 1 24 20m PoE 1 16 Max150m Standardy PoE IEEE802 3 af IEEE802 3 at Obsługiwane protokoły IEEE802 3 10BASE T IEEE802 3u 100BASE TX IEEE802 3ab 1000BASE T IEEE802 3z 1000BASE SX LX FUNKCJE Przyciski 1 przycisk reset dla całego urządzenia Zabezpieczenie przeciwprzepięciowe tak PARAMETRY INSTALACYJNE Wymiary mm 315 szer x 442 gł x 44 wys Masa 3 73kg Zasilanie 230V Pobór mocy urządzenia 420W W...

Страница 27: ...rnet 10 100 B Gniazdo UPLINK Ethernet 10 100 1000 C Gniazdo UPLINK SFP 10 100 1000 D Gniazdo Console E Przycisk resetu ustawień F Diody sygnalizacyjne pracy na portach Ethernet PoE G Diody sygnalizacyjne na portach UPLINK H Dioda sygnalizacyjna zasilania I Gniazdo zasilania 100 240V ROZMIESZCZENIE I FUNKCJA ELEMENTÓW PRZEŁĄCZNIKA Widok z przodu i z tyłu A B C D E F G H I ...

Страница 28: ...ernet 10 100 B Gniazdo UPLINK Ethernet 10 100 1000 C Gniazdo UPLINK SFP 10 100 1000 D Gniazdo Console E Przycisk resetu ustawień F Diody sygnalizacyjne pracy na portach Ethernet PoE G Diody sygnalizacyjne na portach UPLINK H Dioda sygnalizacyjna zasilania I Gniazdo zasilania 100 240V ROZMIESZCZENIE I FUNKCJA ELEMENTÓW PRZEŁĄCZNIKA Widok z przodu i z tyłu A B C D E F G H I ...

Страница 29: ...192 168 1 200 i wpisaniu użytkownika admin i hasła admin ukażą się funkcje przełączni ka Aby zalogować się do menu przełącznika należy ustawić adres IP z tej samej grupy adresowej w karcie sieciowej gdyż ten przełącznik nie ma funkcji serwera DHCP 5 1 W zakładce SYSTEM STATUS możemy dokonać zmiany strefy czasowej serwera NTP czy edytować informacje na temat przełącznika Strefy czasowe Serwer NTP D...

Страница 30: ...ajduje się zakładka Speed limit w której możemy ustawić ograniczyć prędkość transmisji na poszczególnych portach lub dla całego zakresu portów 5 3 Zakładka PoE zbiór funkcji pomocnych w konfiguracji i zarządzaniu budżetem PoE jak również portami Możemy ustawić limity zasilania na portach lub objąć cały zakres portów Dzięki priorytetom możemy ustawić która kamera ma się w pierwszej kolejności w raz...

Страница 31: ... zbyt dużo urządzeń w obrębie jednego przełącznika Po ustawieniu VLANa możemy oddzielić komputery stacji roboczej od kamer czy serwerów 5 5 QoS zakładka daje możliwość ustawienia priorytetów prędkości na portach UWAGA Standardowo wszystkie porty przełącznika znajdują się w VLAN 1 aby dokonywać zmian w przełączniku należy być podłączonym do portu w VLAN ie 1 ...

Страница 32: ... TRUNK zakładka daje możliwość połączenia przełączników kilkoma portami z wyeliminowaniem błędu pętli po za tym zyskujemy wielokrotność prędkości portów W przypadku podłączenie trzema portami zyskujemy 300Mb s rysunek poniżej przedstawia taką implementację UWAGA W tej implementacji TRUNK nie gwarantuje redundancji połączeń ...

Страница 33: ...uży do zarządzania zdarzeniami SNMP Przełącznik wspiera trzy wersje V1 V2 V3 5 8 NETWORK STATISTICS W tej zakładce możemy monitorować FLOW STATISTICS jak również Tablicę MAC 5 8 1 FLOW STATISTICS zakładka w której sprawdzimy status przesłanych pakietów 5 8 2 MAC TABLE to zakładka w której możemy sprawdzić tablice adresów MAC podłączonych do przełącznika ...

Страница 34: ...Holding S A 16 ZARZĄDZANIE PRZEŁĄCZNIKIEM 5 9 SYSTEM MANAGEMENT Zakładka ta służy do w ustawienia adresu IP przełącznika kont użytkowników aktualizacji oprogramowania czy przeglądanie logów 5 9 1 Ustawienia adresu IP 5 9 2 Ustawienia użytkowników 5 9 3 Logi 5 9 4 Menadżer plików ...

Страница 35: ...NV 116S P NV 124S P instrukcja obsługi wer 1 0 Wszelkie prawa zastrzeżone AAT Holding S A 17 NOTATKI ...

Страница 36: ... 124S P instrukcja obsługi wer 1 0 Wszelkie prawa zastrzeżone AAT Holding S A 18 AAT Holding S A ul Puławska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com 2015 07 23 wer 1 0 TW MK ...