IRIG-B Output
The unit features two ports for GPS locked IRIG-B output on BNC connections.
One port is IRIG-B-0xx (DCLS), and one port is IRIG-B-1xx (Sine). The default
setting of both IRIG-B ports is IEEE 1344 with straight binary seconds (SBS).
The configuration of the IRIG-B output can be changed by using the $IMOD
command over the RS-232 port. The IRIG format can be with or without year,
SBS, or IEEE1344 bits enabled.
The following modes are available:
The IRIG-B output is affected by the UTC Offset setting and will report the offset
in positions 64-68 of the 100-bit IRIG-B frame according to the IEEE 1344
format.
DCLS
Sine
0
002
122
1
006
126
✓
2
003
123
✓
3
007
127
✓
✓
4
✓
✓
5
✓
✓
✓
IEEE 1344
IEEE
IEEE w/SBS
IRIG CODES
$IMOD
Year
SBS