USERS GUIDE
NR2310D-O/G
REVISION
M
DATE
071720
Page #:
34
www.novuspower.com
Cold Start: -143 dBm
Reacquisition: -157 dBm
With Novus recommended antenna
Antenna with LNA
Antenna Power
3.5 Vdc, < 20 mA (on center conductor) (factory configurable to 5 Vdc)
Frequency
1574-1607 MHz
Nominal Gain
2 dBic
Amplifier Gain
26 dB
Noise Figure
< 2.0 dB
Out of Band Rejection
Fo±50MHz=60 dBc, Fo±60 MHz
DC Current
<25 [email protected] Vdc
Remote interface & control
Protocol
RS232 NMEA-0183
Connector
DB-9
Location
Rear panel
Protocol
Bit plus stop
Standard Baud Rates
Selectable 4800, 9600, 19200, 38400, 57600 or 115200 bps
SNMP (option)
Remote monitoring & control
Internet
Parameters Monitored
Locally
– present on remote
interface for monitoring
Output amplitude, all power supplies, GNSS lock status, number of
satellites, Built-In test status,
Transaction/Decodable
Commands
English format
Single Monitoring Command
Updated every second
Connector
RJ-45
Environmental and Mechanical
Operating Temperature
0 to 50°C non-condensing
Storage Temperature
-40 to 70°C
Height
1.73
” (1 RU)
Width
19.0”
Depth
10.0”
Weight
5.5 lbs.
AC Input
90 to 264VAC, 50/60Hz
This document is copyright © June 8, 2015 Novus Power Products LLC. All rights
reserved. This document is provided for information purposes only; contents are
subject to change without notice. It is not warranted to be error-free, nor subject to any
other warranties or conditions including implied warranties and conditions of
merchantability or fitness for a particular purpose.