Adjusting the GMT offset will affect the displayed date. As the hour moves across the
International Dateline, the displayed date will reflect the date in the selected time zone, and
not necessarily the GMT date.
2.13 Power Switch
The front or rear panel Power Switch controls AC Power input to the unit. If the optional
DC input is provided with 24V, or a valid DC supply, the unit will operate. In other words,
the front panel switch will not remove power if the optional DC input is powered.
The AC and DC input option provides a redundant and automatic back-up source in the
case of failure of either input.
3.0 Rear Panel
3.1 Channel Outputs
– SMA
There are six 10 MHz outputs across the left-hand side of the rear panel. They are labeled
1 through 6. Nominally, the outputs are 50 Ohm impedance. The PPS is available on the
seventh connector.
3.2 Antenna Input A/B
– SMA
SMA female
– Internal 3.5V supply, 45mA max. In the case of a dual-time-base
configuration, the unit can accept two separate antenna or a single antenna can be used
with an internal splitter. The single antenna configuration gives up 6 dB of sensitivity for a
simpler configuration. The system margin is approximately 30 dB. Therefore, in most
installations the single antenna will work acceptably.