NMS NVR M5, NMS NVR M7
User’s manual ver.1.0
All rights reserved © AAT HOLDING S.A.
6
FOREWORD INFORMATION
3.1. Dimensions
All dimensions are in mm.
Страница 1: ...user s manual NMS NVR M5 NMS NVR M7...
Страница 2: ...rical and electronic equipment for recycling purpose For more information about recycling of this product please contact your local authorities your household waste disposal service or the shop where...
Страница 3: ...to heat build up and damaging the device itself as a consequence 9 Mounting the device on unstable surface or using not recommended mounts is forbidden Improperly mounted device may cause a fatal acci...
Страница 4: ...r Screws User s manual 2 MAIN CHARACTERISTICS 4 x Ethernet PoE IEEE802 3af 15 4W RJ 45 interface 10 100 Mbit s Video and audio channels 16 Recording speed up to 480 fps at 1280 x 720 Recorded stream s...
Страница 5: ...4 x 12 fps for 2592 x 1944 270 fps 9 x 30 fps for 1280 x 720 90 fps 3 x 30 fps for 1920 x 1080 45 fps 3 x 15 fps for 2048 x 1536 36 fps 3 x 12 fps for 2592 x 1944 Recorded Data Search by date time eve...
Страница 6: ...NMS NVR M5 NMS NVR M7 User s manual ver 1 0 All rights reserved AAT HOLDING S A 6 FOREWORD INFORMATION 3 1 Dimensions All dimensions are in mm...
Страница 7: ...tors USB Ports POE Switch Anti vibration bracket Audio input Audio output Ethernet Ports Power ignition module connectors PS2 port DC IN port VGA DVI monitor output COM port 1 4 Digital I O USB Ports...
Страница 8: ...g the antivibration kit to ground NVR should be placed on the flat surface Due to requirements device can be mounted by Screwing rivet screw 1 from the ground Screwing to the ground using universal ho...
Страница 9: ...PUT DC S3 Connection sheme is shown below Connect the power source battery and ignition ACC IN signal to DC Input The minimal recommended cable diameter not including insulation is 2 59 mm 10 AWG The...
Страница 10: ...onally plug the appropriate cable to the S3 connector in the ignition module and the NVR unit as shown on the pictures below The cable is included DC IN 9V 30V 1 V 2 V 3 Ground 4 Ground 5 Ground S3 1...
Страница 11: ...ion of the power supply voltage SW1 DIP Switch 3 Dip Switch 4 SW1 DIP Switch 1 DIP Switch 2 Turn On Turn Off Remark 00 0 off 0 off 11 5V 10 5V Default 01 0 off 1 on 12V 11V 10 1 on 0 off 12 5V 11V 11...
Страница 12: ...1 0 off 1 on 24V 10 1 on 0 off 19V 11 1 on 1 on 12V SW2 DIP Switch 1 Function Remarks 0 0 off Default 3 seconds delay Default 1 1 on Configuration on the DIP Switches 3 4 5 DIP Switch 3 4 5 Turn on de...
Страница 13: ...ignition module 7 FIRST LAUNCH CAUTION English is default language For changing the language follow the steps described further in this chapter First launch requires additional action User will be ask...
Страница 14: ...tton to run NMS full description in chapter 9 1 press the Turn off button to close NMS and show the main screen description in chapter 9 press the X button in right upper corner to close this window w...
Страница 15: ...tion requires an additional login Access to these options is assigned only to an administrator account root Access from other accounts with administrator privileges is restricted The default login is...
Страница 16: ...on which is is a professional solution for video monitoring based on TCP IP CLIENT SERVER networks A wide range of NMS server settings for video streams sharing enables creation of complex monitoring...
Страница 17: ...of the main screen there is a field indicating the status of NMS Possible statuses are Starting Running Closing Stopped NMS login window is shown below Default user is root Turn off button closes the...
Страница 18: ...features Server processing power is mainly used to record streams from the cameras video streaming to NMS Client video display is limited Server Client processing power is is used to record and displ...
Страница 19: ...etwork or not function available only in server and server client modes This function has its significance when installing the NMS in server mode Option is skipped in client mode Pressing the Next ope...
Страница 20: ...tions are described below Details will be presented in the following chapters of the user s manual You can adjust panel layout move enable or disable link and change the panels size what gives you pra...
Страница 21: ...isplay up to 4 streams per window The second video window is also used by LOGS MAPS and EVENTS panels Logs panel PTZ panel Devices and cameras panel Live video and playback panel Application menu Appl...
Страница 22: ...ity for video window display purposes in order to save computing power of a NVR Split screen stream option is configurable in CONFIGURATION DEVICES General tab Split screen streams are shown as greyed...
Страница 23: ...es of all video streams associated with IP device State The IP device status connected disconnected and associated video streams status recording on off recording mode snapshoot playback active PTZ co...
Страница 24: ...d Icon displayed on NMS Client application shows recording available on NMS Server Schedule mode enabled grey icon means that recording is disabled Live view enabled Playback on PTZ camera control on...
Страница 25: ...device or NMS server Date and Time Current NMS server time Initialization attempting to open a video stream Incompatible device Connection error device incompatible with the NMS software Connection li...
Страница 26: ...evice panel allows user to display selected video stream in desired window by clicking RMB and choosing Show position in menu Position 1 means that first screen in division isn t displaying any video...
Страница 27: ...ws in division cause that some streams will not be displayed 9 1 7 NMS user manual Chapter 9 1 and subchapters contain basic information about using the NMS Detailed information can be found in the fu...
Страница 28: ...splays a Nwatch window It is a diagnostic application monitoring the performance of the NMS It contains information about CPU usage number of threads used memory application state and log list 9 3 Men...
Страница 29: ...or via the Internet IPTool utility to find cameras and change their network parameters Remote support runs Team Viewer application In order to get the remote support contact the Novus technical suppor...
Страница 30: ...ns processes CPU usage commit charge and memory information network activity and statistics logged in users and system services Change password allows to change the access password for default user ro...
Страница 31: ...n changing In order to change the screen resolution select the Control panel from the System configuration submenu In Display 1 panel press the Adjust resolution 2 In window Screen Resolution choose d...
Страница 32: ...ked no 3 on the photo in chapter 3 2 of this manual After pressing wait until operating system shutdown User can be prompted to log out of the NMS The device could be also shutdown from the main scree...
Страница 33: ...NMS NVR M5 NMS NVR M7 User s manual ver 1 0 NOTES All rights reserved AAT HOLDING S A 33...
Страница 34: ...2015 12 11 JM MK AAT Holding sp z o o 431 Pulawska St 02 801 Warsaw Poland tel 4822 546 07 00 fax 4822 546 07 59 www novuscctv com...