Novus DC80L Скачать руководство пользователя страница 1

INDEX 

1.

 

INTRODUCTION ........................................................................................... 1

 

2.

 

SAFETY INFORMATION .............................................................................. 2

 

3.

 

MODEL DC80T ............................................................................................. 2

 

3.1.

 

MODEL DC80T GENERAL SPECIFICATIONS ..................................... 3

 

3.2.

 

MODEL DC80T FRONT PANEL ............................................................ 3

 

3.3.

 

MODEL DC80T OPERATING INSTRUCTIONS .................................... 4

 

4.

 

MODEL DC80R ............................................................................................. 5

 

4.1.

 

MODEL DC80R GENERAL SPECIFICATIONS .................................... 6

 

4.2.

 

MODEL DC80R FRONT PANEL ........................................................... 6

 

4.3.

 

MODEL DC80R OPERATING INSTRUCTIONS ................................... 7

 

5.

 

MODEL DC80L ............................................................................................. 8

 

5.1.

 

MODEL DC80L GENERAL SPECIFICATIONS ..................................... 9

 

5.2.

 

MODEL DC80L FRONT PANEL ............................................................ 9

 

5.3.

 

PROTECTION ...................................................................................... 10

 

5.4.

 

MODEL DC80L OPERATING INSTRUCTIONS .................................. 10

 

6.

 

MAINTENANCE .......................................................................................... 13

 

 

 
 
 
 
 
 

1.

 

INTRODUCTION 

The Novus Calibrators series DC80 are portable instruments designed to meet the 

user needs for measuring and simulating signals such as voltage, current, 

resistance, thermocouples and RTDs. The available options depend on the 

particular model. They are: 

 

DC80T, for Thermocouples and mV 

 

DC80R, for RTDs and resistance 

 

DC80L, for linear mV, V and mA (provides internal power supply for 

powering 2-wire transmitters) 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DC80L

Страница 1: ...L SPECIFICATIONS 9 5 2 MODEL DC80L FRONT PANEL 9 5 3 PROTECTION 10 5 4 MODEL DC80L OPERATING INSTRUCTIONS 10 6 MAINTENANCE 13 1 INTRODUCTION The Novus Calibrators series DC80 are portable instruments...

Страница 2: ...e instrument for measurement or simulation 3 MODEL DC80T The MODEL DC80T is capable of measuring and generating mV and thermocouple signals The specifications shown on the tables below are valid for t...

Страница 3: ...to 50 C Shock Random 2 g 5 Hz to 500 Hz Safety 1 meter drop test Power requirements 6 x AAA 1 5 V Battery Size 205 mm x 98 mm x 46 mm Weight 472 g with batteries 3 2 MODEL DC80T FRONT PANEL The keypad...

Страница 4: ...large calibration errors Thermocouple or mV measurement 1 Press the power switch to turn on the calibrator 2 Press the INPUT OUTPUT key to select INPUT mode 3 Press the TC TYPE selection key to config...

Страница 5: ...target instrument OHM meter of RTD meter connected to the calibrator RTD measurement and simulation specifications Mode Range Accuracy C Excitation current mA Input 4 W Input 2 W 3 W Output Pt10 385...

Страница 6: ...mm x 98 mm x 46 mm Weight 472 g including batteries 4 2 MODEL DC80R FRONT PANEL The keypad and display functions are shown below 4 wire input terminal not used for output 2 wire input output terminal...

Страница 7: ...ding value RTD Simulation 1 Press the power switch to turn ON the calibrator 2 Press the INPUT OUTPUT key to select OUTPUT mode 3 Press RTD mode key to select the desired RTD type 4 Press the Incremen...

Страница 8: ...2 wire transmitter The following tables show the DC80L specifications functions and ranges based on a one year calibration period at ambient temperatures ranging from 18 C to 28 C Counts means units o...

Страница 9: ...2 g 5 Hz to 500 Hz Safety 1 meter drop test Power requirement 6 x AAA Size 204 mm L x 99 mm W x 46 mm H Weight 460 g including batteries External power supply 9 Vdc 500 mA 5 2 MODEL DC80L FRONT PANEL...

Страница 10: ...calibrator Fuse 2 is probably blown out if the calibrator reads 0 000 in mA input mode even under the presence of a current input signal 5 4 MODEL DC80L OPERATING INSTRUCTIONS DC mV and V measurements...

Страница 11: ...egative test lead black to the target equipment 7 For changing the output value use the increment decrement keys and the V mV mode key until the desired value is displayed DC mA measurement a Using ex...

Страница 12: ...splay 4 Plug the red test lead into the LOOP jack and the black one to the mA jack 5 Connect the test leads such that the current enters the red lead and returns to the power supply through the black...

Страница 13: ...ough the black lead 7 To change the output value press the increment decrement keys and or the mA mA mode key Accessories a pair of Test Leads 6 MAINTENANCE Cleaning Periodically wipe the case with a...