NOVOTEST NVS P1 Скачать руководство пользователя страница 6

2 INTENDED USE

2.1 Operational limitations

The operation of the device must be carried out under the conditions of influencing

factors and taking into account the parameters of the controlled objects in accordance with

the agreed technical characteristics, and the device must also be used within the framework

of its technical characteristics.

The user who is familiar with the operating documentation for this device is allowed to

work with the device.

After transporting the device to the place of operation at a negative ambient temperature

and bringing it into a room with a positive temperature, in order to avoid failure due to

moisture condensation, keep the product in the package for at least 2 hours.

During storage, the Vibration Meter Pen must be in a packing container, the battery

charge must be at least 50%.

2.2 Preparing the device for use

Carry out an external examination of the device, make sure that there are no mechanical

damages. If there is any dirt, wipe the display and the housing of the device with a clean

cloth.

Before using the device, make sure that there is sufficient charge in the Vibration Meter

Pen. When the low battery indicator appears, which is located on the right side of the display,

you need to connect the device to a PC using a USB cable or to a charger

Note - When using the Vibration Meter Pen for the first time, it is necessary to conduct an

external examination of the device and, without turning it on, recharge it until the charge indicator is

full by connecting it to a PC using a USB cable. The battery charge level is shown on the right side of

the display. After that, 2-3 complete charge and discharge cycles of the battery should be performed.

Prepare the surface of the controlled object, it should be as clean, smooth, and free of

contamination as possible.

2.3 Using the device
2.3.1 Turning on

The device is switched on by short-term pressing of the "

" button, after which you

can select the required operating mode of the Vibration Meter Pen.

2.3.2 Measurement modes

Switching between modes is carried out by pressing the "

" key. The device operates

in the following modes: vibration acceleration measurement mode (m / s

2

); vibration speed

measurement mode (mm / s); vibration displacement measurement mode (mm); mode of the

ratio of peak acceleration and vibration speed.

Vibration acceleration measurement mode

Acceleration measurement is especially useful for localizing high frequency vibrations

and is therefore suitable for detecting faults in bearings and gearboxes. Acceleration is

measured in m / s².

Vibration velocity measurement mode

Содержание NVS P1

Страница 1: ...NVS P3...

Страница 2: ...rking and sealing 5 1 6 Packing 5 2 INTENDED USE 6 2 1 Operational limitations 6 2 2 Preparing the device for use 6 2 3 Using the device 6 2 3 1 Turning on 6 2 3 2 Measurement modes 6 2 3 3 Measuremen...

Страница 3: ...necessary to read this manual as the device operation must be carried out by persons who are familiar with the operation principle and the device design Correct and effective use of the hardness test...

Страница 4: ...function after 20 seconds of inactivity the Vibration Meter Pen will turn off automatically The device is powered by a built in battery The instrument is widely used in petrochemical and machinery in...

Страница 5: ...uses the LCD 2 3 4 5 1 1 vibration sensor 2 Vibration Meter Pen body 3 Modes key 4 LCD display 5 key for switching on and measuring Fig 1 1 Vibration Meter Pen NVS P1 1 5 Marking and sealing The manuf...

Страница 6: ...ed on the right side of the display you need to connect the device to a PC using a USB cable or to a charger Note When using the Vibration Meter Pen for the first time it is necessary to conduct an ex...

Страница 7: ...or with the object press and hold the key the device will start measuring vibration The measurement result is displayed on the LCD During of measuring vibration the device makes cyclic measurements at...

Страница 8: ...ntees the conformity of the device to the requirements of the technical conditions under the user s compliance with the conditions of transportation storage and operation and timely maintenance at the...

Страница 9: ...r short term storage and between use the device should be stored in the intended packaging The storage area should be free from vapors of aggressive substances acids alkalis and direct sunlight The de...

Отзывы: