background image

 

Design and manufacture of devices and 

systems for nondestructive testing 

 

Pinhole Detector NOVOTEST ED-3D

 

 

9

 

 

10.4. At transportation, loading and storage in a warehouse the 
device should be preserved against blows, pushes and moisture 
influence. 
 
10.5. For an exception of condensation of moisture in the device at 
its carrying from a frost in a warm room, it is necessary to sustain 
before use the device within 6 hours at room temperature. 

 
11. Maintenance 

Maintenance of the device is made by the manufacturer in case of 
detection of malfunctions in operation of the device. 

 

12. Warranty 

13.1. The manufacturer guarantees normal operation of the device 
for 12 months, from the moment of sale, and undertakes to make its 
repair during this term at emergence of breakages and refusals. 
 
12.2. Warranty don't extend in case of violation of seals, service 
conditions, transportation and device storage, and also in the 
presence of mechanical damages of the electronic unit and/or an 
electrode holder. 
 
12.3. The guarantee doesn't extend on cables and batteries. 

 

Содержание ED-3D

Страница 1: ...PINHOLE DETECTOR NOVOTEST ED 3D MANUAL 2013...

Страница 2: ...roduction 2 2 Appointment 2 3 Technical characteristics of the device 2 4 Packing list 3 5 Device action principle bodies of indication and control 4 6 Marking container and packing 6 7 Preparation fo...

Страница 3: ...ty of dielectric coverings on products from electro carrying out materials 2 2 Operating conditions of operation of the device air temperature from 0 to 40 relative humidity of air to 95 at 30 3 Techn...

Страница 4: ...Tolerance of thresholds of operation 10 3 7 The size of a contact surface of the sponge 50 200 mm 3 8 The power of the device is carried out from three NiMH of storage batteries or elements of a power...

Страница 5: ...s of operation of the device the annex of control tension to a metal product and a covering with the put electrolit and fixings of course of a current at electrolit penetration to metal in places of v...

Страница 6: ...Design and manufacture of devices and systems for nondestructive testing Pinhole Detector NOVOTEST ED 3D 5 Figure 1 Bodies of indication and control...

Страница 7: ...electrolyte to the one water liter 7 3 To execute cleaning of oxide films on a sponge installation site on an electrode the holder and clamping platinum 7 4 Fix a sponge on an electrode holder 7 5 Wit...

Страница 8: ...of the device the indicator of the chosen control tension will begin to blink and there is a faltering sound signal 7 12 For monitoring procedure a clip of the crocodile type of a connecting cable No...

Страница 9: ...act surface of an electrode holder and clamping plates disconnect cables 9 Precautionary measures 9 1 The persons after instructing and certified on the II qualifying group for safety measures at work...

Страница 10: ...om temperature 11 Maintenance Maintenance of the device is made by the manufacturer in case of detection of malfunctions in operation of the device 12 Warranty 13 1 The manufacturer guarantees normal...

Страница 11: ...D 10 MANUAL 013 001 0812 Pinhole detector NOVOTEST ED ype NOVOTEST 3D Serial number ______________________ Manufacturing date ____ ____________20___ Manufacturer Scientific and Technical Centre Indust...

Страница 12: ...__________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Отзывы: