background image

10  

System Start-Up 

1. Plug the valve into an approved power source. 

2. When  power  is  supplied  to  the  control,  the  screen  will  display  “INITIALIZING  WAIT 

PLEASE” while it finds the service position.  

3. Start an Immediate Manual Regeneration.  The valve will immediately start moving to the 

BACKWASH position. 

4. Open the inlet on the bypass valve slowly and allow water to enter the unit. Allow all air 

to escape from the unit before turning the water on fully then allow water to run to drain 
for 3-4 minutes or until all media fines are washed out of the softener indicated by clear 

water in the drain hose. 

5. Press any button to advance to the RINSE position.  Check the drain line flow.  Allow the 

water to run for 3-4 minutes or until the water is clear. 

6. The  valve  will  automatically  advance  to  the  SERVICE  position  after  the  RINSE  cycle  is 

complete. Open the outlet valve on the bypass, then open the nearest treated water fau-
cet and allow the water to run until clear, close the tap and replace the faucet screen. 

7.  Program  time,  date,  and  number  of  days  between  regenerations  into  controller  using 

Programming Instructions 

Start-up Instructions

 

Key Pad Configuration 

SETTINGS  This function is to enter the basic set up infor-

mation required at the time of installation. 

MANUAL 
REGEN 

This function is to initiate an immediate or 
delayed manual regeneration. 

DOWN / 
UP 

Increase or decrease the value of the settings 
while in the  programming mode. 

DELAYED REGENERATION 

Press and release the MANUAL REGEN. But-
ton to set a delayed regeneration that will 
occur at the regeneration time.  The main 
display page will show DELAYED REGEN ON.  

To cancel press and release the MANUAL RE-
GEN. Button.  The main display page will 
show DELAYED REGEN OFF. 

IMMEDIATE REGENERATION 

To start an immediate regeneration (or step 
valve through each position), press and hold 
the MANUAL REGEN. Button for 3 seconds 
(until beeps).  The valve will start an immedi-

ate regeneration.  Press any key to skip to 
the next cycle. 

Manual Regeneration (Step / Cycle Valve)

 

Содержание 485MM-100

Страница 1: ...rovided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection befo...

Страница 2: ...anual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping...

Страница 3: ...Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat so...

Страница 4: ...10x54 12x52 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Plumbing Connections Electrical Requirements Water Temperature Water Pressure 485NU 75...

Страница 5: ...ilitates the removal of iron and manganese by raising the pH This enables an iron filter to be used Periodic backwashing cleans the bed Addi tional media may be required six months to two years after...

Страница 6: ...Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transform...

Страница 7: ...pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipm...

Страница 8: ...when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also inclu...

Страница 9: ...9 Filter Installation...

Страница 10: ...ated water fau cet and allow the water to run until clear close the tap and replace the faucet screen 7 Program time date and number of days between regenerations into controller using Programming Ins...

Страница 11: ...2 2 2 1 1 1 1 1 1 1 1 8 6 4 4 3 2 2 2 2 1 1 1 1 1 1 1 1 9 4 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 10 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 1 Backwash Frequency Programming Instructions TIME OF DAY YEAR MONTH DAY Tim...

Страница 12: ...nd Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be displayed To manually scroll through th...

Страница 13: ...up to 30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypas...

Страница 14: ...r to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on th...

Страница 15: ...2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank a...

Страница 16: ...0048 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FI...

Страница 17: ...17 Filter Exploded View...

Страница 18: ...BOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CL...

Страница 19: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 20: ...A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1...

Страница 21: ...21 Power Head Exploded View...

Страница 22: ...0426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141...

Страница 23: ...k if central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2...

Страница 24: ...or installation is provided and then the warranty period shall be from the date thereof Life Time Warranty on Mineral Tanks Novo Water Conditioning Products will provide a replacement mineral tank to...

Отзывы: