background image

   

Novo Clear 485 

Automatic Water Filters 

Multi-Media 

Neutralizing 

Carbon 

In

stal

lation an

d  

Oper

ation M

anual

 

REVISION # 

REVISION DATE  NOVEMBER 12, 2012 

1.  Read all instructions carefully before operation. 
2.  Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified 

lubricant to all seals. 

3.  This system is not intended for treating water that is microbiologically unsafe or of unknown 

quality without adequate disinfection before or after the system. 

Proud member of Canadian Institute of Plumb-

ing & Heating. 

Canadian Head Office

 

655 Park St.

 

Regina, SK S4N 5N1

 

 

Eastern Sales & Distribution

 

20 Steckle Place, Unit 21

 

Kitchener ON N2E 2C3 

Proud member of Canadian Water Quality Asso-

ciation. 

Содержание 485MM-100

Страница 1: ...rovided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection befo...

Страница 2: ...anual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping...

Страница 3: ...Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat so...

Страница 4: ...10x54 12x52 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50 lbs 60 lbs 78 lbs 95 lbs 138 lbs Plumbing Connections Electrical Requirements Water Temperature Water Pressure 485NU 75...

Страница 5: ...ilitates the removal of iron and manganese by raising the pH This enables an iron filter to be used Periodic backwashing cleans the bed Addi tional media may be required six months to two years after...

Страница 6: ...Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transform...

Страница 7: ...pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipm...

Страница 8: ...when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also inclu...

Страница 9: ...9 Filter Installation...

Страница 10: ...ated water fau cet and allow the water to run until clear close the tap and replace the faucet screen 7 Program time date and number of days between regenerations into controller using Programming Ins...

Страница 11: ...2 2 2 1 1 1 1 1 1 1 1 8 6 4 4 3 2 2 2 2 1 1 1 1 1 1 1 1 9 4 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 10 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 1 Backwash Frequency Programming Instructions TIME OF DAY YEAR MONTH DAY Tim...

Страница 12: ...nd Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be displayed To manually scroll through th...

Страница 13: ...up to 30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypas...

Страница 14: ...r to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on th...

Страница 15: ...2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank a...

Страница 16: ...0048 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FI...

Страница 17: ...17 Filter Exploded View...

Страница 18: ...BOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CL...

Страница 19: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 20: ...A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1...

Страница 21: ...21 Power Head Exploded View...

Страница 22: ...0426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141...

Страница 23: ...k if central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2...

Страница 24: ...or installation is provided and then the warranty period shall be from the date thereof Life Time Warranty on Mineral Tanks Novo Water Conditioning Products will provide a replacement mineral tank to...

Отзывы: