Trouble Shooting 

Issue

Possible Cause

Possible Solution

1. No power supply.

Check electrical service, fuse, etc.

2. Defective circuit board.

Replace faulty parts.

3. Power failure.

Reset time of day.

4. Defective meter.

Replace turbine meter.

1. By-pass valve open.

Close by-pass valve.

2. Out of salt or salt level below water level.

Add salt to tank.

3. Plugged injector / screen.

Clean parts.

4. Flow of water blocked to brine tank.

Check brine tank refill rate.

5. Hard water in hot water tank.

Repeat flushing of hot water tank required.

6. Leak between valve and central tube.

Check if central tube is cracked or o-ring is 
damaged.  Replace faulty parts.

7. Internal valve leak.

Replace valve seals, spacer, and piston 
assembly.

8. Reserve capacity setting too low.

Increase reserve capacity.

9. Not enough capacity.

Increase salt dosage.

1. Refill time is too high.

Check refill time setting.

2. Defective flow control.

Replace.

1. Iron or scale build up in line feeding unit.

Clean pipes.

2. Iron build up inside valve or tank.

Clean control and add resin cleaner to clean 
bed.  Increase regeneration frequency.

3. Inlet of control plugged due to foreign 
material.

Remove piston and clean control valve.

4. Deteriorated resin.  (Maybe caused from 
high chlorine or chloramines.)

Re-bed unit.  Consider adding carbon pre-
treatment.

1. Air in water system.

Check well system for proper air eliminator 
control.

2. Incorrect drain line flow control (DLFC) 
button.

Check for proper flow rate.

1. Plugged injector or screen.

Clean parts.

2. Valve not regenerating.

Replace circuit board, motor, or control.

3. Foreign material in brine valve.

Clean parts.

4. Unit not drawing brine.

Check for vacuum leak in brine line 
connections.

1. Drain line flow control is plugged.

Clean parts.

2. Injector or screen is plugged.

Clean parts.

3. Inlet pressure too low.

Increase pressure to 25 PSI.

4. Internal valve leak.

Replace seals, spacers, and piston assembly.

5. Safety valve closed.

Check for leak in brine line connections.  
Replace safety float assembly.

6. Vacuum leak in brine line.

Check for leak in brine line connections.  
Tighten all connections.

7. Drain line has kink in it or is blocked.

Check drain line.

H. Valve continuously 
cycles.

1. Defective position sensor PCB.

Replace faulty parts.

1. Valve settings incorrect.

Check valve settings.

2. Foreign material in control valve.

Clean control.

3. Internal leak.

Replace seals, spacers, and piston assembly.

4. Piston is stuck in position.  Motor may have 
failed or gears have jammed or disengaged.

Check for power to motor.  Check for loose 
wire.  Check for jammed gears or gears 
disengaged.  Replace faulty parts.

J. Valve makes beeping 
sound.

1. The piston has not advanced to the next 
cycle position properly.

Check for power to motor.  Check for loose 
wire.  Check for jammed gears or gears 
disengaged.

I. Flow to drain 
continuously.

G. Unit fails to draw brine.

A. Unit fails to initiate a 
regeneration cycle.

B. Water is hard.

E. Resin in drain line.

C. Salt use is high.

D. Low water pressure.

F. Too much water in brine 
tank.

Содержание 485HTO-100

Страница 1: ...lly unsafe or of unknown quality without adequate disinfection before or after the system Proud member of Canadian Institute of Plumb ing Heating Canadian Head Office 655 Park St Regina SK S4N 5N1 Eas...

Страница 2: ...treating water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Страница 3: ...ces Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nigh...

Страница 4: ...ke product improvements which may deviate from the specifications and descriptions stated herein without obligation to change previously manufactured products or to note the change Models are not test...

Страница 5: ...not covered by the war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to...

Страница 6: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Страница 7: ...7 Installation...

Страница 8: ...e full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on th...

Страница 9: ...determine the salt dosage and capacity for the system For SIM units choose IRON MN WATER TYPE Select WELL OTHER if any Iron or Manganese is present or if the water source is not clean 1NUT turbidity...

Страница 10: ...perates The regeneration cycle lasts up to 180 minutes During this time you may hear water running intermittently to the drain About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 G...

Страница 11: ...Precision Brining Regeneration Process Step Name Description 1 Brine Making A precise calculated amount of fresh water is added to the brine tank to make enough brine to regenerate only the exhausted...

Страница 12: ...Use only crystal water softener salt Check the salt level monthly It is important to main tain the salt level above the water level To add salt simply lift the salt lid and add the salt directly into...

Страница 13: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Страница 14: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Страница 15: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Страница 16: ...16 Brine Tank Res Up Feeder Assembly Step 3 Install brine well Feed wick from feeder into the opening in the brine well cap...

Страница 17: ...020041 844 TANK 75 I 1 25020042 948 TANK 100 I 1 25020043 1054 TANK 150 I 1 25010058 1252 TANK 200 I 1 25030007 1465 TANK 300 I 1 60010012 PARALLEL ADAPTOR G 1 80127755 9 TANK FLEX PIPE H 1 80127756 7...

Страница 18: ...Quantity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE C...

Страница 19: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Страница 20: ...65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26...

Страница 21: ...21 Power Head Exploded View...

Страница 22: ...arge Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT85 Mounting B11 1 5031009 BNT85HE Brine Gear Upflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141 Washer 4x12 B14 1 5056...

Страница 23: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Страница 24: ...or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and not subject to...