user guide
9 digital
Страница 1: ...user guide 9 digital...
Страница 2: ...fore operating this medical equipment it is important to read this User Guide and understand the operating instructions and safety precautions Failure to do so could result in patient injury and or da...
Страница 3: ...page Safety Precautions 4 6 Product Overview 7 Installation Operation 8 15 Troubleshooting 16 17 Cleaning 18 19 Maintenance 20 Technical Specifications 21 26 Warranty Information 27...
Страница 4: ...s are isolated from the internal metal components with protecting insulation WARNING The double insulated system is intended to protect the user from shock resulting from a break in the Control Unit s...
Страница 5: ...ence between the Control Unit and other devices may occur If interference is suspected move equipment from sensitive devices or contact Novis Healthcare Only plug into a grounded power outlet using th...
Страница 6: ...a precision product Use care when handling or transporting Dropping or other sudden impacts may result in damage to the unit Before attaching the Control Unit to the foot board of the bed ensure the...
Страница 7: ...Mute completes the profile The visible and audible alarm function has a number of indications depending on the cause of the failure On the side of the Control Unit are four male air connectors for qui...
Страница 8: ...es from the shipping cartons Inspect all items for any damage that may have occurred during shipping Any damage or missing components should be reported to a Novis Healthcare Service Centre as soon as...
Страница 9: ...c mode will automatically revert to Alternation Mode after 20 minutes for patient safety E comfort setting buttons Press arrows to increase or decrease pressure setting Eight pressure settings from so...
Страница 10: ...NT Make sure that the attachment of the Mattress Replacement does not interfere with the movement or operation of the bed The system is designed to operate in a controlled environment free from extrem...
Страница 11: ...alternating LED will illuminate to indicate that the system is ready for use system automatically defaults to alternation mode after initialisation f Once the Mattress Replacement is fully inflated b...
Страница 12: ...mately 20 minutes reassess system function and patient comfort In the event of a system error the alarm will activate and pressure LEDs will flash indicating a fault For quick reference a comfort sett...
Страница 13: ...ure an airtight seal IMPORTANT Do not position the system to make it difficult to operate the CPR Tag Perform a Bottoming Out test after re inflating the mattress following rapid deflation see page 12...
Страница 14: ...ed Alarm LED flashes and an audible alert sounds to indicate the Control Unit or Mattress is experiencing a fault The LED will remain illuminated until the fault is cleared The audible alarm can be si...
Страница 15: ...st see page 12 to ensure the patient is adequately supported and not touching bed base mattress deflation and storage 1 Press the power button for at least three seconds to switch off the Control Unit...
Страница 16: ...set the alarm turn off Power and press the Alarm Mute button 2 Check all air hoses along the inside of the Mattress each should be firmly connected Check each air cell is securely attached to its conn...
Страница 17: ...row 2 To check effective system performance conduct a bottoming out test as described on page 12 NOTE If the problem is not resolved please contact an authorised Novis Healthcare Service Centre alarm...
Страница 18: ...required If cleaning or disinfecting is required do not disconnect the hoses from the air cells Never or allow fluid and moisture to enter air cells and air hoses NOTE Refer to the top cover wash tag...
Страница 19: ...ctants may be used provided manufacturer s instructions are followed All cleaning agents and disinfectants must be thoroughly rinsed off and the item dried before storage Failure to do this may result...
Страница 20: ...your system in optimal operating condition Failure to keep the filters clean will result in system downtime and increase repair costs It is recommended that the air filter be replaced annually Air fil...
Страница 21: ...ght 11 6 kg Control Unit Dimensions Height 270 mm Width 315 mm Depth 120 mm Weight 3 5 kg Cell material 210D nylon Base material 420D Polyamide Polyurethane Cover material Multi stretch Polyamide Poly...
Страница 22: ...standards and compliances associated with the Control Unit and its use Caution Consult accompanying documents Class II equipment Manufacturer Serial number Type BF applied part Operating Instruction...
Страница 23: ...ernal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emission CISPR 11 Class B The system is suitable for use in all es...
Страница 24: ...uality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines EC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle...
Страница 25: ...a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note1 At 80 MHz and 800 MHz the higher frequen...
Страница 26: ...z to 2 5 GHz d 2 333 P 0 01 0 117 0 117 0 233 0 1 0 369 0 369 0 738 1 1 167 1 167 2 333 10 3 689 3 689 7 379 100 11 667 11 667 23 333 For transmitters rated at a maximum output power not listed above...
Страница 27: ...se and service be free from faulty parts manufacture or workmanship for a period of 24 months commencing from the date of purchase Subject to the provisions of the Australian Consumer Law Novis Health...
Страница 28: ...accordance with EC Directive on Medical Devices 93142lE EC Control Number 95CG Classified by Underwriter s Laboratory Inc for UL 2601 1 standard for Medical Electrical Equipment unit 12 12 mars road...