Novis APMBL-L01 Скачать руководство пользователя страница 8

8

User Guide 

BetterLiving

System Preparation

Hang the control unit over the foot end of the 
bed, using the in-built spring loaded hanging 
hooks. Pull the hooks by the rubber tabs to 
prevent accidentally trapping your fingers.

Ensure it is secure before use; failure to do so 
could result in equipment damage.

Connect the umbilical connectors to the 
corresponding sockets on the side of the 
control unit.  Listen for a click as confirmation 
the connector is locked in place.

  Straighten any twists in the  

umbilical air hoses. 

  Ensure the umbilical air hose is not  

trapped between the mattress and bed. 

Feed power cord through the cord retention 
loops along either side of the mattress base. 
Insert power cord base into the side of the 
control unit, then plug into an appropriate 
electrical outlet and switch on mains power.  

The Power indicator will glow amber, 
confirming the control unit is connected to a 
power source.

  Ensure the power cord is not under strain; 

is free from obstruction; and is secured 
safely so as not to be a trip hazard.

Содержание APMBL-L01

Страница 1: ...MATTRESS OVERLAY AlternatingMattressReplacement Overlay U S E R G U I D E MATTRESS REPLACEMENT...

Страница 2: ...sional Ifyouhaveanyquestions pleasecontactNovis Healthcareon1300738885 NovisHealthcarehasapolicyofcontinuous productimprovementandreservesthe righttoamendspecificationspresentedin thisguide Informatio...

Страница 3: ...osesandCPRrelease Controlunit Powercord Userguide Carrybag Itisrecommendedthatallpacking materialsandmanualsbekeptinthecarry bagprovided foreaseofstorageand or transport Intended Use Thepreventionandt...

Страница 4: ...ble pressure injury prevention strategy avoid wearing clothing that may cause areas of localised damage due to creases seams objects in pockets etc Never use sharp objects or electrically heated blank...

Страница 5: ...oxygenornitrousoxide Donotuseinthepresenceofsmoking materialsoropenflame airflowingthroughthemattresswillsupport combustion Donotopenthecontrolunit riskof electricalshock Referservicingtoqualified ser...

Страница 6: ...a which may risk damage to the mattress replacement BedBase UmbilicalCord FootSymbol Attachtothebedbysecuringtheadjustable straps locatedontheundersideofthemattress baseundereachbedend Onaprofilingbed...

Страница 7: ...ddingfromthemattressand placethemattressoverlayontheexisting mattress orsuitablefoamunderlay Printedtopcoverfacingupwardsand umbilicalhosetowardsthebaseofthebed CheckCPRsealingvalveisclosed the turnin...

Страница 8: ...clickasconfirmation theconnectorislockedinplace Straighten any twists in the umbilical air hoses Ensure the umbilical air hose is not trapped between the mattress and bed Feedpowercordthroughthecordre...

Страница 9: ...lie a person or any weight on the mattress during initial inflation Wheninitialinflationiscomplete the PressureSettingandMaxInflateindicators willextinguish toindicatethesystemis readyforuse Thesyste...

Страница 10: ...nderneaththepatientandfeelforadeflatedcellunderthepatient slower spine Theinnerstaticcellwillremaininflated howeveryourhandshouldeasilyslidebetween patientandbase Ifyourhandcanpassunderthepatient then...

Страница 11: ...dicatethemodecurrentlyactive SeeModeonpage12formoredetails D Power Pressandholdforaminimumofthreeseconds toturnsystempoweronandoff Green light poweron E Alarm Mute Turnsaudiblealarmofftemporarily Pres...

Страница 12: ...to ensureallaircellsareinflated Beforemovingthemattress ensurethecontrol unitisswitchedoffanddisconnectedfrom mainspower Disconnecttheumbilicalairhose fromthecontrolunitbyunpluggingthequick releasecon...

Страница 13: ...flateallcells Pressthereleasebuttonsontheumbilicalcord connectorstoreleasetheairhoses Onceairhasbeenreleasedfromthesystem detachthemattressfromthebed Rollthe mattressfromheadendtofootendtoremove addit...

Страница 14: ...rol It is recommended that the system is cleaned every two weeks if in constant use Base Cleaning Swabthemattressbaseandcellswithasolutionofsodiumhypochloriteorsimilar upto10 000 ppmavailablechlorine...

Страница 15: ...moisture Asoftbristlednylonbrushcanbeusedtogentlycleancrevices Ensure the control unit is disconnected from mains power before cleaning Donotspraydisinfectantdirectlyontothecontrolunit orimmersetheun...

Страница 16: ...nen dust Replace withnewfilterifneeded Ensuretheaircellsarefreeofdamageorleaks Forfastermattressreinflationoncetheairleakhasbeenclosed pressMAXINFLATEandwaituntil thePressureLossindicatorextinguishes...

Страница 17: ...propriateaccordingthelegislation Please beenvironmentallyresponsibleandcontact yourlocalauthorityonavailableoptionsto recycle thisproductatitsendoflife Service Life Theexpectedservicelifeofacontroluni...

Страница 18: ...m canbeestimatedusingtheequationapplicabletothefrequencyofthetransmitter wherepisthemaximumoutputpower ratingofthetransmitterinwatts W accordingtothetransmittermanufacturer NOTE1 At 80 MHz and 800 MH...

Страница 19: ...0 15MHz 80MHz PortableandmobileRFcommunications equipment shouldbeusednoclosertoanypartofthecontrolunit includingcables thantherecommendedseparation distancecalculatedfromtheequationapplicabletothe fr...

Страница 20: ...B 217Hz 0 2 0 3 9 9 745 780 810 800 960 GSM800 900 TETRA800 iDEN 820 CDMA850 LTE Band5 Pulse modulationB 18Hz 2 0 3 28 28 870 930 1 720 1700 1990 GSM1800 CDMA 1900 GSM1900 DECT LTEBand1 3 4 25 UMTS Pu...

Страница 21: ...z MAXIMUM CURRENT 0 2 to 0 1A FUSE RATING T2AL250V MIN MAX PRESSURE 20 60mmHg 6mmHg PROTECTION TYPE ClassIITypeBF INGRESS PROTECTION RATING IP21 HEIGHT x WIDTH x DEPTH 195 x 265 x 120mm WEIGHT 2kg MAT...

Страница 22: ...ed toitspremisesoroneofitsAuthorisedService Agentsinpersonorfreightprepaidbyyou Noviswillundertakeatitsoption torepairor replace freeofcharge eachproductorpart thereofontheconditionthat Theproductfoun...

Страница 23: ...ndthefailure doesnotamounttoamajorfailure Toobtain compensation youwillneedtoprovided documentaryevidenceofthelossordamage sufferedanddocumentaryevidencethatsuch lossordamagewasareasonableforeseeable...

Отзывы: