Novi DB-301 Скачать руководство пользователя страница 9

Black

0009

Black

0009

6.

Attach doorbell module to doorbell
mounting bracket (secure with retaining
screw later after adjusting volume).

7.

Disconnect low-voltage (24 VAC)
interior  wires from existing doorbell
transformer.

8.

Disconnect the two wires inside the
doorbell and twist them together.
Secure and insulate wires with a wire
nut. 

9.

Route 18 AWG bell wire from the
location of the wires disconnected in
Step 7 to a nearby 110 VAC outlet
location.

10. Connect existing wires to the 18 AWG

bell wire with two wire nuts. 

11. Connect the other end of the 18 AWG

bell wire to the AC adapter terminals
(either wire to either terminal).

ALIGN TOP

EDGE FIRST

SWING

CLOSED

SECURE WITH

RETAINING SCREW

REMOVE WIRES FROM
SECONDARY SIDE OF
DOORBELL TRANSFORMER

REMOVE WIRES 
FROM TERMINALS

TWIST WIRES TOGETHER
AND SECURE WITH WIRE NUT

USE 18 AWG BELL WIRE
BETWEEN EXISTING
DOORBELL WIRE AND 
110 VAC OUTLET

WIRE LEADING
TO OUTLET 
LOCATION

EXISTING
DOORBELL
WIRES

CONNECT WIRES
TO TERMINALS
(EITHER WIRE TO
EITHER TERMINAL)

INSTR

,INSTL,DB-301,ENG

L

ISH

Linear P/N: 216082 B

Si

z

e

: 5.500" x 8.500"

Materi

al

: 60 Lb. W

h

ite C

oated w

ith 80 Lb. W

h

it

e Coated Cov

e

r

Ink: Bl

ack

Sc

al

e: 1-1

7

Содержание DB-301

Страница 1: ...ity System Installation Guide Model DB 301 LOCK CALL TALK A B C OFF POWER IN USE By Linear By Linear INSTR INSTL DB 301 ENGLISH Linear P N 216082 B Size 5 500 x 8 500 Material 60 Lb White Coated with...

Страница 2: ...SE PERIODS Always turn the unit off and unplug when it is not being used or left unattended for long periods of time OBJECT AND LIQUID ENTRY Never push objects of any kind into the unit through the ca...

Страница 3: ...by the manufacturer or sold with the product Any mounting of the product should follow the manufacturer s instructions and should use a mounting accessory recommended by the manufacturer OVERLOADING...

Страница 4: ...ystem Provides safety security and peace of mind Easy to install and operate NOTE WIRELESS TECHNOLOGY can infer sound transmission is carried on the airwaves or through the electrical wiring of your h...

Страница 5: ...outside your door without actually opening it This occurs if all outlets around the property are connected to the same electrical loop that the household wiring is on Most homes in the U S will have...

Страница 6: ...B C OFF POWER IN USE By Linear 1 7 8 WI 3P 3 CHANNEL INTERCOM DB 300 DOORBELL MODULE By Linear OFF 9 10 12 13 11 2 4 3 5 6 INSTR INSTL DB 301 ENGLISH Linear P N 216082 B Size 5 500 x 8 500 Material 6...

Страница 7: ...between two or more wireless intercoms 6 TALK BUTTON Press to talk Release to listen 7 MICROPHONE High gain microphone monitors your voice 8 SPEAKER Clearly transmits pure static free two way voice c...

Страница 8: ...4 Set doorbell module channel switches to select intercom channel For Channel A set Switch 1 ON and Switch 2 OFF For Channel B set Switch 1 OFF and Switch 2 ON 5 Connect existing wires to terminals on...

Страница 9: ...the 18 AWG bell wire with two wire nuts 11 Connect the other end of the 18 AWG bell wire to the AC adapter terminals either wire to either terminal ALIGN TOP EDGE FIRST SWING CLOSED SECURE WITH RETAIN...

Страница 10: ...cket to wall using the two screws provided 2 Drill holes to provide wiring access from doorbell mounting bracket to a nearby 110 VAC power outlet 3 Route 18 AWG bell wire from doorbell mounting bracke...

Страница 11: ...es to AC adapter terminals either wire to either terminal 8 Plug the adapter into an unswitched 110 VAC power outlet CONNECT WIRES TO TERMINALS EITHER WIRE TO EITHER TERMINAL ALIGN TOP EDGE FIRST SWIN...

Страница 12: ...BELL button This should produce a doorbell sound 3 Person at intercom should now press and hold down TALK button and speak to the person at doorbell Then release to wait for reply 4 The person at door...

Страница 13: ...dapter is plugged into If all of the above have been tried without success disconnect adapter and doorbell module and reconnect with a few feet of wire Plug adapter into an outlet and plug wireless in...

Страница 14: ...IONS 3 x 5 1 4 x 1 1 4 WEIGHT 8 1 4 oz 3 CHANNEL WIRELESS INTERCOM POWER SOURCE 110 120 VAC AT 60 Hz CARRIER FREQUENCY A 230 kHz B 260 kHz C 290 kHZ RF OUTPUT POWER 100 mW AUDIO OUTPUT POWER 500 mW MO...

Страница 15: ...Black 0015 Black 0015 INSTR INSTL DB 301 ENGLISH Linear P N 216082 B Size 5 500 x 8 500 Material 60 Lb White Coated with 80 Lb White Coated Cover Ink Black Scale 1 1...

Страница 16: ...k 0016 Black 0016 Copyright 1999 Linear Corporation 216082 B INSTR INSTL DB 301 ENGLISH Linear P N 216082 B Size 5 500 x 8 500 Material 60 Lb White Coated with 80 Lb White Coated Cover Ink Black Scale...

Отзывы: