![Novexx Rewinder 2000 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/novexx/rewinder-2000/rewinder-2000_service-manual_1712056029.webp)
02/17 Rev. 02
SERVICE MANUAL
Attachment, Setup, Service
Rewinder
2000
11
Setting the sensor current
Befor using the rewinder for the first time, the sensor current must be set by
a potentiometer at the rewinder [3].
[3] The pot. can be accessed through a slot in the back cover of the rewinder.
Action
Display
Note
1. Select
parameter
SERVICE
FUNCTION > Sensor test
.
Sensor test
Sens: 0.01 xxx
xxx is the value supplied
by the sensor
2. Press the Feed button
repeatedly until
Sensor test
Sens: 4.01 xxx
4.01 = sensor peripheral
devices
3. Set the rewinder pot. [1] so
that a value between 20
and 30 is displayed.
Sensor test
Sens: 4.01 27
Dancer arm in zero
position [2]; 27 = set value.
4. Move the dancer arm to the
final position (towards the
support leg). Check the
displayed value*.
Sensor test
Sens: 4.01 130
130 = set value (example)
in the final position; Value
difference = 103 (o.k.)
*) The value with the dancer arm in its final position must be at least 80 higher than the value
in zero position, which was set in step 3. Most important ist the difference between the two
values in the two end positions: the difference must equal/be higher than 80, ideally 100.
Repeat step 3 and set a higher value in the zero position, if the difference is too little.
Pot. (P101)
Z0139E.cdr
Turn counter-clockwise =>
Sensor current decreases
Displayed value increases
Turn clockwise =>
Sensor current increases
Displayed value decreases
Rewinder (section)