Service Mechanics
Front left housing
Tools
• Torx screwdriver, size 20
• Open-ended spanner, size 7
Removing
1. Remove the rear hood.
See chapter
2. If any: Unplug the connector of the option from the
D-Sub connector.
3. Remove the bolt [10A].
4. Screw off the nut. Remove the retaining ring and
the washer [11A].
5. Carefully lift the housing. Unplug the connector
[11B] from the control panel board. Remove the
housing.
Installation
Perform the installation in the reverse order to the re-
moval. Note the following:
Plug in the connector again before assembling.
Assembly sequence at stud bolt: Base plate - wash-
er – retaining ring - nut.
[10] Fixing bolt at the front left housing with (here with D-Sub
connector).
[11] Loosen the fastening (A) and the connector (B).