Service manual
XLP 504 / XLP 506
05/2018 | 04
199
Malfunctions
One of the following status messages may follow second:
Third may follow one of the status messages listed below:
5001 No gap found
No gap found or several blank labels fed.
Acknowledge by pressing key 4.
Check the print mask for gap definition (material length).
Check whether the correct material has been inserted.
Check that the photoelectric switch is clean.
Check material feed and position of photoelectric switch.
5002 Material end
Material end. Material no longer in the gap LS.
1. Press key 4 in order to acknowledge the status report.
2. Insert material and check the position of the photoelectric switch, correct if necessary.
3. Press key 4. Processing of the job continues, gap is reinitialised.
5003 Lever open
The print head pressure lever was opened, during:
• the feeding of material or
• printing.
The error message is automatically acknowledged with the closing of the print head pressure lever.
Status
Missing output stage for the following device:
Cutter motor
Print head liftmotor
Ribbon motor
[Tab. 36] Those status messages indicate, that the device is not connected to the I2C bus.
Status
5020 I2C Timeout xx
5021 I2C Conf. xx
5022 I2C Busy xx
5023 I2C LAB xx
5024 I2C BER xx
5025 I2C Polling xx
[Tab. 37] Status messages, which help to further locate the I2C bus error.
xx = Device ID of the concerned device (see tab. 38).
Nr
Device
0
CPU
4
Peripheral motor
8
Rewinder (internal)
15
I/O board
16
EEPROM
17
Realtime-clock
[Tab. 38] Assignment of device IDs as used in status messages related to the I2C bus.
Содержание XLP 504
Страница 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Страница 2: ......
Страница 218: ...Service manual XLP 504 XLP 506 05 2018 04 218 Malfunctions System Memory Font downl area System Memory Free store size ...
Страница 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Страница 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...