04/13 Rev. 1.12-02
USER / SERVICE MANUAL
Mounting/Setup
LA-TO / LA-TO XL
Settings
26
Setting the on-off valve
The on-off valve [33A] is a safety relevant part of the
applicator. It prevents an abrupt backward movement
of the applicator plate, when the compressed air is
switched on.
The on-off valve is factory-set. The setting is fixed with
locking varnish.
If the vacuum plate of the LA -TO moves back to the
home position very abruptly, as soon as the com-
pressed air is switched on, the on-off valve is not set
correctly or it is defective.
A
faulty setting
has to be corrected as described be-
low.
Exchange a
defective valve
. Set the new valve as
described below (not required, if the valve was ordered
at Avery Dennison).
Tools:
•
Screwdriver, small
•
Screw locking varnish
Setting:
1. Turn set screw [33B] up to the limit in direction
„slow“.
2. Plug in the supply air hose [33C]. Pull off the out-
hoses [33D].
The arrow at the valve shows the flow direction.
3. Set the supply air pressure to 6 bar.
4. Slowly turn out the set screw, until the supply air
starts streaming through the valve.
5. Turn out set screw ½ turn further.
6. Switch off the supply air. Pull off the supply hose.
7. Lock set screw with locking varnish.
WARNING
High risk of getting fingers or hands crushed
due to abruptly backwards moving vacuum
plate.
Set the on-off valve as described below.
Be cautious when switching on the com-
pressed air.
[33] On-off valve at the LA -TO (RH).