USER / SERVICE MANUAL
Mounting/Setup
LA-TO / LA-TO XL
Assembly
15
Mounting to ALS 30x
Tools
2.5/4 mm hex socket screwdriver
Assembly
1. Switch-off the ALS 30x.
2. Remove the four set screws [16A] and take off the
dispensing edge with holding rods [16C].
3. Push the LA -TO onto the holding rods and fasten it
there using the locking screws [16B].
4. Insert the holding rods into the cross arm [16D] and
fix it with the four set screws [16A].
5. Connect the cable to LA -TO and ALS 20x.
Connection to standard signal interface [11A]
(article no.: A7074)
Connection to applicator interface [12A]
(article no.: A8752)
6. Connect the interlock circuit of the protective guard
to the LA -TO [9B].
See chapter
Connecting an interlocking guard
Connecting an interlock circuit is mandatory.
The LA -TO must not and cannot be operated with-
out.
7. Install the pressure regulator.
See chapter
Installing the pressure regulator
8. Connect the compressed air supply.
See chapter
Connecting the compressed air hose
9. Switch-on the ALS 20x.
10. Make setting in the parameter menu.
See chapter
11. Adjust the LA -TO.
See chapter
[16] Mounting the LA -TO to an ALS 30x.
[17] Connecting to an ALS 30x (standard signal interface).
[18] Connecting to an ALS 30x (optional applicator interface).