Service Manual
ALS/XLS 20x/256/272
02/2019 | 03
252
Repair
OPENING THE CASING
Removing the dust/splash guard (ALS/XLS 20x)
At ALS 20x machines, which are equipped with the IP65 option, the connection cover boxes [192A,
B] must be removed before opening the housing.
Prerequisites:
– The machine is de-energised.
Tools:
– Hexagon socket driver SW 2.5 and 3
Unscrew four screws [192A arrows].
Remove the cover box[192A] off carefully.
– By doing so, the power connector on the inside of the cover box is removed.
If the cover box for interfaces [192B] is prevailing:
If prevailing: Pull the Ethernet connector off from the cover box.
Unscrew four screws [192B arrows].
Remove the cover box [192B] carefully. While doing so, unplug the interface cables from the
machine.
[192] Housing with IP65 equipment (IT2).
A
Cover box for power supply connection
B
Interface cover box
B
A
Содержание ALS/XLS 204