01/13 Rev. 5.05-01
USER MANUAL
Attachment, Setup
Rewinder
2000
12
Checking the sensor current setting
(Only for 64-xx and AP 5.4)
Call
SERVICE FUNCTION > Rewinder values
.
Rewinder Values
xxx <--------------------> yyy
•
xxx = Sensor value in zero position
•
yyy = Sensor value in final position (Dancer arm at the printer side limit)
The difference yyy – xxx must
at least
be 80 (best: 100). If the difference is
less, the sensor current setting must be changed, see chapter Setting the
sensor current below.
Setting the sensor current
Befor using the rewinder for the first time, the sensor current must be set by
a potentiometer at the rewinder (see Fig. 3).
Fig. 3 The pot. can be accessed through a slot in the back cover of the rewinder.
Action
Display
Note
1. Select parameter
SERVICE
FUNCTION > Sensor test
.
Sensor test
Sens: 0.01 xxx
xxx is the value
supplied by the
sensor
2. Press the Feed button
repeatedly until
Sensor test
Sens: 4.01 xxx
4.01 = sensor
peripheral devices
Pot. (P101)
Z0139E.cdr
Turn counter-clockwise =>
Sensor current decreases
Displayed value increases
Turn clockwise =>
Sensor current increases
Displayed value decreases
Rewinder (section)