background image

4

Novell Sentinel 6.1 SP1 Hotfix 2

n

ov

do

cx (e

n)

  16
 Ap
ril 20

10

Sentinel Collector Builder

Sentinel Data Manager

Solution Designer

5

Stop the Sentinel service running on the machine:

On Windows: use Windows Service Manager to stop the Sentinel service.

On Linux/Solaris: run the 

$ESEC_HOME/bin/sentinel.sh stop

 command.

6

Open the command prompt.
For most Windows systems and Linux/Solaris, you can log in as any user to open the prompt. 
For Windows Vista, you must open the command prompt as an Administrator, using the 
following instructions.

6a

Go to 

Start > All Programs > Accessories

6b

Right-click 

Command Prompt

 and select 

Run as administrator

.

If User Access Control  is enabled and you are logged in as a user with administrator 
privileges, a User Access Control window appears to notify that Windows needs your 
permission to continue. 

6c

Click 

Continue

.

If you are logged in as a user without administrative privileges, then you are prompted to 
authenticate as an administrative user.

7

On the command line, return to the extracted hotfix top-level directory and run the script to 
start the hotfix installer:

On Windows: 

service_pack.bat

On Unix*: 

./service_pack.sh

After you run the script, the 

Sentinel 6.1 SP1 is the prerequisite for this hotfix 

installation

 message appears.

8

Perform the following:

On Windows: Press Enter if Sentinel 6.1 SP1 is already installed and continue with the 
installation or Ctrl+C to terminate the installation and install Sentinel 6.1 SP1.

On Unix: Press y if Sentinel 6.1 SP1 is already installed and continue with the installation 
or n to terminate the installation and install Sentinel 6.1 SP1.

9

Press Enter when prompted to start the hotfix installation procedure.

10

After the installation completes, log out and log in to apply the environmental variable changes.

11

Repeat 

Step 1

 through 

Step 10

 on every Sentinel server and client machine that has Sentinel 

software installed.

12

Restart Sentinel services on all machines:

On Windows: use the Windows Service Manager to start the Sentinel services. 

On Unix: run 

$ESEC_HOME/bin/sentinel.sh start

 

Содержание SENTINEL 6.1 SP1 HOTFIX 2 - READ ME 9-2009

Страница 1: ...the latest software fixes and enhancements to an existing installation of Sentinel 6 1 SP1 and 6 1 SP1 Hotfix 1 This hotfix must be installed on all existing Sentinel 6 1 SP1 clients and servers This...

Страница 2: ...arsed by the Collector Manager Sentinel 6 1 SP1 Hotfix 2 enables the EventRouter to operate in server and client modes on both DAS machines and Collector Manager machines The Collector Manager install...

Страница 3: ...partitioned or archived the PatchDb script might fail if the AUDIT_RECORD table is too large relative to the amount of temporary tablespace available There are two approaches to ensure that the PatchD...

Страница 4: ...d to authenticate as an administrative user 7 On the command line return to the extracted hotfix top level directory and run the script to start the hotfix installer On Windows service_pack bat On Uni...

Страница 5: ...he Oracle dba group The user has the Java 1 6 executable as the PATH variable TIP You can run the PatchDb script directly on the database server machine if the prerequisites are met However in some en...

Страница 6: ...lation 10 After the installation is complete check for any errors If there are no errors the Sentinel database patch installation is complete If there are errors resolve the errors by referring to the...

Страница 7: ...dress of the SQL Server Sentinel database machine SQL Server database instance name if any Port number of the SQL Server database Name of the SQL Server database to patch ESEC by default 1 for the Win...

Страница 8: ...the date and time format to your local time zone see the Java Web site http java sun com j2se 1 6 0 docs api java text SimpleDateFormat html 1 Edit the SentinelPreferences properties file On Windows...

Страница 9: ...efect Number Description 530554 Sentinel Control Center SCC and Sentinel Solution Designers SSD launchers shortcuts do not launch the respective Sentinel applications on WIndows Workaround For SCC rig...

Страница 10: ...ctive stream for a prolonged time period 498871 ESM pays attention to the default attribute for Connection methods 459625 SDM no longer lets you create impossible configurations with at least MS SQL 4...

Страница 11: ...comply with all export control regulations and to obtain any required licenses or classification to export re export or import deliverables You agree not to export or re export to entities on the cur...

Отзывы: