9 DISTANCE MEASUREMENT
Select a screen view which indicates horizontal distance from the zero point to the bucket
measuring point.
Note
Check the accuracy of the system before starting the work (see chapter 2.4).
When measuring horizontal distance, the starting point is always “0.00”. The measurement value is
zeroed at the starting point. The display indicates the distance from the starting point to the bucket.
Move the bucket to a stake or other reference point. Zero the measurement value. The reading
“0.00” appears on the screen (Figure 59).
When the bucket is moved away from the excavator, the distance value increases. When the
bucket is moved towards the excavator, the distance value decreases (Figure 60).
Xsite EASY | User manual | Page 45 of 52
Figure 60. Distance measurement
Figure 59. Zeroing the reading on a stake