SMART6 User Manual Rev 3
56
Table 5: SMART6 Communication/Power Cable Pin-outs
A.2.2
SMART6 Connector and Cable Requirements
Custom cables for installing the SMART6 can be created using the following guidelines:
•
Wire size: must be 0.5 mm-1.25 mm (20-16 AWG)
•
Batt+ connection must be protected by 5 A fast blow fuse
•
Serial data signals (TxD, RxD, signal ground) must be run in shielded cable. Connect shields
to ground at SMART6 end only
•
CAN signal conductors must be twisted (40 twists/m, 12 twists/ft)
•
Use only the recommended mating connectors listed below. Use only gold plated pins
The connector used in the SMART6 is an “AMPSEAL” dust and water sealed type produced by Tyco. The
following part numbers pertain to the mating connector required to make connections to the SMART6. These
numbers are provided for information only and are not available from NovAtel as separate parts.
Signal Name
J1
J2
J3
J4
Label
COM1_TXD
1
2
COM1_RXD
2
3
COM2_TXD
3
2
COM2_RXD
4
3
AUX_TXD
8
2
AUX_RXD
13
3
COM1 GND
5
5
COM2 GND
5
AUX GND
5
EVENT MARK IN (MKI) GND
MKI GND
Emulated Radar GND
ER GND
Pulse Per Second GND
PPS GND
CAN+
6
CANI+
CAN-
7
CANI-
PWR RET (GND)
9
BATT-
Emulated Radar Out
10
ER_OUT
EVENT MARK IN (MKI)
11
MKI
PPS
12
PPS
PWR INPUT
14
BATT+
Failure to observe the given cable construction guidelines and fusing requirements in this
section may result in damage to the wiring or equipment and voiding the warranty.
NovAtel recommends tying to ground any floating input lines.