APPENDIX C LN-200 IMU in Universal Enclosure
OEM7 SPAN Installation and Operation User Manual v14
296
rings and the alignment of corners. Start with the round pilot hole indicated in
below, then press the assembly into place.
Figure 126: Installing the Enclosure Body to the Base
6. While squeezing and holding the enclosure body and base together to maintain tight contact, carefully turn
the assembly over and place it on its top, as shown in
Figure 127: Screw Enclosure Base to Body
Using a 3 mm hex bit, lightly fasten four equally spaced M4 screws to hold the parts together. Use thread-
locking fluid on all screws. Install the remaining screws in similar fashion. Tighten all screws to 1.36-1.58
N-m (12-14 lb-in). Do not over-tighten.
Figure 127: Screw Enclosure Base to Body
7. Ensure the product identification label, the logo plate and the center of navigation labels are properly affixed