APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
230
A.15.2 OEM-IMU-ISA-100C Sensor Specifications
Gyroscope Performance
Input range
±495 °/seconds
In-run bias stability
≤0.05 °/hour
Scale factor repeatability
≤100 ppm
Scale factor non-linearity
≤100 ppm
Angular random walk
0.012 °/√hour
Accelerometer Performance
Range
±10 g
In-run bias stability
≤100 μg
1 year scale factor repeatability
≥1250 ppm
Scale factor non-linearity
≤100 ppm
Velocity random walk
≤100 μg/√Hz
Data Rate
IMU Measurement
200 Hz
Table 121: OEM-IMU-ISA-100C IMU Per-
formance
A.15.3 OEM-IMU-ISA-100C Electrical and Environmental
Electrical
Input Power
+3.3 V, ±5.25 V, ±15 V, -15 V (optional)
Power consumption
≤10 W (typical)
16 W (maximum)
Connector
44 pin HD D-Sub, male
Table 122: OEM-IMU-ISA-100C Electrical Specifications
Environmental
Temperature, operational
-40°C to +71°C
Table 123: OEM-IMU-ISA-100C Envir-
onmental Specifications