Enclosure Cables Technical Specifications
Appendix H
OEM6 Family Installation and Operation User Manual Rev 12
199
H.1.2
I/O DB-HD15 Strobe Port Cable (NovAtel part number 01018651)
The strobe lines on the FlexPak6 and FlexPak6D can be accessed by inserting the female DB-HD15
connector of the I/O strobe port cable into the I/O port. The other end of this cable is provided without a
connector to provide flexibility. The jacket insulation is cut away slightly from the end but the insulation on
each wire is intact. The cable is approximately 2 m in length. See
Figure 100, I/O DB-HD15 Strobe Port
on page 199. This cable is RoHS compliant.
Figure 100: I/O DB-HD15 Strobe Port Cable
Table 53: I/O Strobe Port Cable Wiring
I/O Port Pin
I/O Port Signal
I/O Port Cable Wire Color
Not connected
Blue
5
Ground
White/Grey
9
MODE
Red
10
EVENT2
Green
11
EVENT1
Orange
12
VARF
Black
a
13
a. Not available on the FlexPak6D.
ERROR
Violet
14
PV
Yellow
15
PPS
Brown
All unlisted pins on the cable are not connected.