
62
EuroPak-15a Receiver User Manual Rev 5
Chapter 5
Commands
5.3.12
PULSEBLANKING
Enable/Disable Pulse Blanking
The PULSEBLANKING command should only be used by advanced users.
This command enables or disables digital pulse blanking. By default, the digital pulse blanking is enabled. The
sensitivity of the digital pulse blanking may be adjusted using the switch field.
Syntax:
Message ID: 519
Examples:
PULSEBLANKING L1 5
Table 30: Frequency Switch
Table 31: Pulse Blanking Switch
PULSEBLANKING
FREQUENCY
SWITCH
Field
Field
Name
Valid Values
Description
Format
Binary
Bytes
Binary
Offset
1
header
This field contains the
Abbreviated ASCII
command name. See
H
0
2
frequency
L1 or L5
Pulse blanking frequency. See
below.
Enum
4
H
3
switch
0-127
Pulse blanking switch using
thresholds. See
Ulong
4
H+4
ASCII
Description
L1
GPS L1 and Galileo L1 frequency
L5
GPS L5 and Galileo E5a frequency
ASCII
Description
0
Disable pulse blanking
1-127
Enable pulse blanking