WAAS GUS Signal Generator User Guide Rev 1
Chapter 5
Messages
Table 16: Resulting
Q
Modulation Format
5.1.3.3
Initialization Command
This command specifies the initial range (modulo 1 second) value to be used by the Signal Generator.
shows the initialization data fields for an L1 configured Signal Generator.
shows the
initialization data fields for an L5 configured Signal Generator at 500 SPS.
Table 17: L1 Initialization Command Fields
N/A
1
0
1
Disable
Disable
Enable
Disable
N/A
1
1
0
Disable
Disable
Disable
Enable
N/A
1
1
1
Disable
Disable
Disable
Disable
D3
D7
D4
D6
PRN Code
Manchester
Code
Neumann-
Hoffman
Code
Symbols
1
0
0
0
Enable
Enable
Disable
Enable
1
0
0
1
Enable
Disable
Enable
Disable
1
0
1
0
Enable
Disable
Disable
Enable
1
0
1
1
Enable
Disable
Disable
Disable
1
1
0
0
Disable
Enable
Disable
Enable
1
1
0
1
Disable
Disable
Enable
Disable
1
1
1
0
Disable
Disable
Disable
Enable
1
1
1
1
Disable
Disable
Disable
Disable
0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
D3
D1
D5
D2
PRN Code
Manchester
Code
Neumann-
Hoffman
Code
Symbols
Byte Position
Description
Valid Range
Value / Scale Factor
Byte [7]
Symbol Rate/RF
Configuration
0 or 128
Set to zero ‘0’
Byte [8]
Sub-Chip
0 – 255
Initial DDS Sub-Chip
Byte [9:10]
Code Chip Advance
0 – 1022
Initial Code Chip Advance
Byte [11:12]
Symbol Advance
and Symbol 1 ms epoch
Bits [0:14] = 0 – 499
Bit [15:15] = 0-1 (MSB)
Initial Symbol Advance
and Symbol 1 ms epoch
Byte [13:14]
I coder init G2.
Byte[13] = init bits 0-7
Byte[14] = init bits 8-9
G2(I) channel coder
initialization value at zero chip
count