CONTROL DESCRIPTIONS

 

 

1.  Circuit Breaker Switch 

The green circuit breaker switch is used to show power is going to Novair and protect the controls of the 
machine. This adds power to the GFCI outlets to allow daisy chaining of equipment and will trip if 
maximum amperage is exceeded.  
 

2.  Variable Speed Dial 

The variable speed dial can be set from 200 -700cfm depending on the desired vacuum flow. The 
maximum setting is shown to the left as the dial is first turned to the “ON” position.

 

 

3. 

Auxiliary “GFCI” protected Outlet -115v 

The auxiliary GFCI outlet can be used 

to daisy chain “

No More

” the 3 units together. The maximum of 

12 Amps when the unit is in the “

OFF

” position and 9 Amps when the unit is in the “

ON

” position. You 

can attach other pieces of equipment to this but are limited to the maximum amp draw. When the outlet 
is working properly the green light is lit on circuit breaker. 

 
Auxiliary Outlet -230v (Not Shown) 

The auxiliary 230voutlet can be used to daisy chain “

No More

” the 3 units together. The maximum of 6 

Amps when the unit is in the “

OFF

” position and 4 Amps when the unit is in the “

ON

” position. You can 

attach other pieces of equipment to this but are limited to the maximum amp draw. When the outlet is 
working properly the green light is lit on circuit breaker. 
 

CAUTION:

 

If the GFCI trips “UN-PLUG” the unit from the power source and check for any 

potential hazards (damaged power cord, moisture, too many units plugged, etc.) causing a 
power surge. Once unit is evaluated plug the unit into a new power source and push the reset 
button. If unit operates as normal: continue use, if unit trips again contact Novatek at 866-563-
7800. 

 
4.  Filter change indicator  

The indicator light will alert the operator when filters are loaded or when air flow is greatly decreased. 
The light will come on once the pressure reaches approximately 3

” of water column. Filters should be 

inspected and replaced. Once filters are replaced the light will go off. If light stays on contact Novatek at 
866-563-7800. 

 

5.  Power Cord 
 

Firmly insert the female end of the power cord into a grounded power source. Visually inspect the cord 
for any damage before installation into power source. 
 

CAUTION:

  

A loose, corroded, ill fitted or damaged cord or plug can cause injury. If cord has any 

of these issues should be re-placed immediately.

   

 

 

Содержание F0700

Страница 1: ......

Страница 2: ...manual for any purpose other than your own personal use is a violation of the United States copyright laws March 1 2016 issue 1 0 Specifications subject to changes without notice If you have any ques...

Страница 3: ...cles Some dust created by power sanding sawing and grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or other reproductive harm Some examples o...

Страница 4: ...ION I Introduction 5 SECTION II General Description 5 SECTION III Routine Maintenance 5 Control Descriptions 6 SECTION IV Prior To Use 7 Operation 7 SECTION V Replacement Of Filters 7 SECTION VI Wirin...

Страница 5: ...ilter The final stage is the 99 99 0 3 micron HEPA Filter utilized in areas where an extremely high level of filtration is desired The NOVAIR 700 requires a 115V 3 Amp 230v 2 Amp single phase power so...

Страница 6: ...maximum of 6 Amps when the unit is in the OFF position and 4 Amps when the unit is in the ON position You can attach other pieces of equipment to this but are limited to the maximum amp draw When the...

Страница 7: ...ency of filter replacements Once the filters load and the pressure reaches approximately 3 the visual alarm will light CAUTION Always wear approved respirators and personal protective equipment during...

Страница 8: ...is has a gasket the other does not Insert the side with the gasket of the HEPA filter first and press firmly against the housings internal rib F Install the housing filter frame and reinstall the 8 h...

Страница 9: ...www novatekco com toll free 866 563 7800 tele 610 363 7800 fax 610 935 1945 sales novatekco com 9 WIRING DIAGRAM 230v...

Страница 10: ...www novatekco com toll free 866 563 7800 tele 610 363 7800 fax 610 935 1945 sales novatekco com 10 SECTION VII Schematic...

Страница 11: ...r death H Never operate the unit if there is any possibility of contact with the blower wheel I It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and effici...

Страница 12: ...thorization number must be clearly marked on the outside of the package being returned Any returned merchandise that does not have a return merchandise authorization number clearly marked on the outsi...

Отзывы: