19.0 INSTRUCTIONAL TROUBLESHOOTING
SCREENS
Examples are shown below.
If you need more information about a particular alarm,
press and a more detailed explanation of the alarm
will appear, if available. Some even have photos with
instructions on how correct the issue.
Press
to see those screens
Press to view possible solutions to resolve an alarm.
20.0 ADDITIONAL TROUBLESHOOTING
PROCEDURES
20.1 Material Is Not Being Conveyed
• If pulling material from a Gaylord, make sure the plastic
bag is not being pulled into the material lance.
• Make sure the Vacuum receivers are not being over-
filled, causing the unit to dead-head.
• Adjust the overload setting on the 3MS motor starter
for the conveying blower.
Phoenix motor-starter configuration instructions
The configuration sequence is as follows:
1. Stop the motor involved, you cannot adjust the set-
point while the motor starter is active.
2. Press the reset button for
more than 2 seconds (but less
than 6) to show the current set-
point. The 4 lights on the front
of the controller will now
indicate the adjustment. The
chart on the next page shows
the light codes.
3. Press the reset button for 6 seconds until the green
power light flashes once. The adjuster is now
operational. This potentiometer will increase or
decrease the amperage set-point and display the
set-point using the 4 LEDs.
4. Press the reset button again to store the value.
5. Press the reset button for more the 2 seconds (but
less than 6 ) to confirm the current set-point.
If the motor starter is reset several times in rapid
succession the motor starter will activate a time-delay
which prevents the motor starter from being reset for
approximately 20 minutes.